Date Text
2025-01-22 15:24:35.00000SHEET PV-4:
 1] INDICATE IF EXTERIOR SERVICE EQUIPMENT IS COMPRISED
 OF A METER-MAIN OR OF SEPARATE COMPONENTS
 2] SHOW ALL EXISTING BREAKERS IN EXTERIOR SERVICE PANEL
 WHERE PV INTERCONNECTION IS PERFORMED. CONSIDERING BUS
 RATING AND 125% OF PV INPUT CURRENT, SPECIAL
 LIMITATIONS AND LABELING WILL BE REQUIRED PER 705.12
 (B)(3)(3).
 3] SHOW OVERCURRENT PROTECTION FOR EXISTING INTERIOR
 PANEL. BUS MUST BE PROTECTED AT A VALUE NOT EXCEEDING
 ITS RATING.