Date Text
2024-06-27 11:16:38.00000CORRECTIONS SUBMITTED BY: ALYSSA/
 PERMITSARASOTA@FREEDOMFOREVER.COM
2024-06-12 08:46:02.00000SHEET PV-4: EXISTING SYSTEM NOTE ON ONE-LINE DIAGRAM
 INDICATES TWELVE IQ7A MICROINVERTERS (MAX 1.45 AMPS
 OUTPUT EACH). THIS DATA AGREES WITH APPROVED PLANS FROM
 THE ORIGINAL INSTALLATION UNDER PERMIT #21100224.
 ASSUMING INSTALLED AS SUCH, THE EXISTING SYSTEM TOTAL
 COMBINED OUTPUT IS 12 X 1.45 = 17.4 AMPS.
  
 1] ALTER RIGHT-HAND COLUMN OF EACH PLAN SHEET TO SHOW
 ACCURATE OUTPUT DATA FOR EXISTING SYSTEM
 2] ON SHEET PV4, CHANGE OVERCURRENT PROTECTION IN
 COMBINER FOR EXISTING SYSTEM TO 25 OR 30 AMPS
 3] ON SHEET PV4, CHANGE OVERCURRENT PROTECTION IN PV
 DISCONNECT TO 45 OR 50 AMPS
 4] ON SHEET PV7, CHANGE AC CURRENT LABEL TO SHOW
 MAXIMUM COMBINED OUTPUT OF 33.23 AMPS (BOTH EXISTING
 AND PROPOSED SYSTEMS)
  
 SHOULD THE EXISTING SYSTEM USE ANY DIFFERENT
 MICROINVERTERS, PLEASE PROVIDE PICTURE VERIFICATION,
 WRITTEN VERIFICATION ON COMPANY LETTERHEAD, AND A
 REVISED SET OF PLANS INDICATING CORRECT SYSTEM
 PARAMETERS.