Date Text
2022-08-09 17:10:22.00000SHEET PV-3: INCREASE CONDUCTORS IDENTIFIED AS #5 AND #6
 TO MINIMUM #3 COPPER. THESE CONDUCTORS DO NOT SUPPLY
 THE ENTIRE DWELLING UNIT AND THEREFORE ARE NOT SUBJECT
 TO DERATING PER 310.15 (B)(7).
  
 OTHER: AN ATTACHED ELECTRICAL PERMIT IS REQUIRED FOR
 ISSUANCE OF THIS SOLAR PERMIT; THE SCOPE OF WORK
 EXTENDS BEYOND A SIMPLE INTERCONNECTION OF THE PV
 SYSTEM.