2020-08-04 16:03:08.00000REVISION #3, SIX PAGES RECEIVED. THE FOLLOWING
 CORRECTIONS ARE REQUIRED.
 1] SHEET PV-2: INSERT NOTE ON DRAWING INDICATING
 COMPLIANCE WITH FLORIDA FIRE PREVENTION CODE
 11.12.2.2.2, AND CLEARLY SHOWING MINIMUM THREE FOOT
 SEPARATION BETWEEN MODULES & ROOF RIDGE.
 2] SHEET PV-4: 30A PV DISCONNECT IS TOO SMALL FOR
 COMBINED INVERTER OUTPUT.
  