Plan Review Notes For Permit 18070555
Permit Number 18070555
Review Stop FIRE
Sequence Number 1
Notes
Date Text
2018-09-18 10:24:25.00000TO: ERIC LONGSHORE, BUILDING OFFICIAL
 FROM: JAMES E. BRANCA, SR., FIRE MARSHAL
 DATE: JUNE 20, 2018
 RE: ROYAL OAKS TRIPLEX 11, 12, 13, PERMIT # 18070555
 I HAVE REVIEWED THESE PLANS FOR CONFORMANCE WITH THE
 FLORIDA FIRE PREVENTION CODE, 6TH EDITION, AND NEED THE
 FOLLOWING ISSUES RESOLVED:
 1. THIS BUILDING IS REQUIRED TO HAVE A SUPERVISED
 AUTOMATIC FIRE SPRINKLER SYSTEM. (SEE LIFE SAFETY CODE
 30.3.5)
 2. SMOKE ALARMS MUST COMPLY WITH SECTION 30.3.4.5 AND
 9.6.2.10 OF THE LIFE SAFETY CODE.
 3. CARBON MONOXIDE ALARMS MUST COMPLY WITH SECTION
 30.3.4.6 OF THE LIFE SAFETY CODE.
 4. WALL SCHEDULES ARE NOT CLEARLY IDENTIFIED.
 5. THE “DEN” IN UNIT 2 NEEDS A SECONDARY MEANS OF
 ESCAPE TO COMPLY WITH SECTION 30.2.1.2 AND 24.2 OF THE
 LIFE SAFETY CODE.
 ALL REFERENCES TO THE LIFE SAFETY CODE ARE FOR THE
 FLORIDA SPECIFIC EDITION.
 PLEASE HAVE THE APPLICANT ADDRESS THESE ISSUES. IF
 THERE ARE ANY QUESTIONS I CAN BE REACHED AT
 863-385-1112
  
 30.2.1.2 MEANS OF ESCAPE WITHIN THE DWELLING UNIT SHALL
 COMPLY
 WITH THE PROVISIONS OF SECTION 24.2 FOR ONE- AND
 TWO-FAMILY
 DWELLINGS.
 24.2* MEANS OF ESCAPE REQUIREMENTS.
 24.2.1 GENERAL. THE PROVISIONS OF CHAPTER 7 SHALL NOT
 APPLY TO
 MEANS OF ESCAPE, UNLESS SPECIFICALLY REFERENCED IN THIS
 CHAPTER.
 24.2.2 NUMBER AND TYPES OF MEANS OF ESCAPE.
 24.2.2.1 NUMBER OF MEANS OF ESCAPE.
 24.2.2.1.1 IN DWELLINGS OR DWELLING UNITS OF TWO ROOMS
 OR MORE,
 EVERY SLEEPING ROOM AND EVERY LIVING AREA SHALL HAVE
 NOT LESS THAN
 ONE PRIMARY MEANS OF ESCAPE AND ONE SECONDARY MEANS OF
 ESCAPE.
 24.2.2.1.2 A SECONDARY MEANS OF ESCAPE SHALL NOT BE
 REQUIRED
 WHERE ONE OF THE FOLLOWING CONDITIONS IS MET:
 (1) THE BEDROOM OR LIVING AREA HAS A DOOR LEADING
 DIRECTLY TO THE
 OUTSIDE OF THE BUILDING AT OR TO THE FINISHED GROUND
 LEVEL.
 (2) THE DWELLING UNIT IS PROTECTED THROUGHOUT BY AN
 APPROVED
 AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH 24.3.5.
 24.2.2.2 PRIMARY MEANS OF ESCAPE. THE PRIMARY MEANS OF
 ESCAPE SHALL BE A DOOR, STAIRWAY, OR RAMP PROVIDING A
 MEANS OF
 UNOBSTRUCTED TRAVEL TO THE OUTSIDE OF THE DWELLING UNIT
 AT STREET OR
 THE FINISHED GROUND LEVEL.
 24.2.2.3 SECONDARY MEANS OF ESCAPE. THE SECONDARY MEANS
 OF
 ESCAPE, OTHER THAN AN EXISTING APPROVED MEANS OF
 ESCAPE, SHALL BE
  
2018-07-23 15:28:13.00000TWO SET OF PLAN SENT TO COUNTY FIRE FOR REVIEW-CARRIER