Date Text
2005-09-30 16:34:41.00000CORRECTIONS MADE
2005-09-06 15:27:31.000001. NEED SITE PLAN.
 2. PLANS SHOW 12X16 MONO FOUNDATION AND
 DETAILS SHOW STEMWALL FOUNDATION.
 3. CHANGED ONE BATHROOM DOOR TO MEET
 HANDICAP CODE.
 4.ON FOUNDATION PLANS, INTERIOR FOOTING
 DONT MATCH OR SOME FOOTINGS MISSING SEE
 TRUSS ENGINEERING.
 5. GARAGE DOOR DESIGNED PRESSURES DO NOT
  
 MEET OR EXCEED OPENING PRESSURES.
 6.NEED PRODUCT APPROVALS ON METAL
 ROOFING TO BE USED.
 7.NO ELECTRIC SHOWN IN BONUS ROOM, AND I
 ADDED DOOR TO STRAIGHT STAIRWAY. ARE
 BOTH STAIWAYS TO BE INSTALLED?
 8.IF STRAIGHT STAIRS ARE TO BE INSTALLED
 I NEED THEM DRAWN IN ON FIRST FLOOR.