Date Text
2005-04-20 08:58:34.000001. NO TRUSS PLANS OR ENGINEERING
 SHOWING
 MAJOR UPLIFTS AND TIE DOWNS.
 2. NO ENERY FORM
 3. NO DETAILS SHOWING ATTACHMENT
 BETWEEN
 BLOCK AND POURED CONCRETE COLUMNS.
 4. SEVERAL PLACES ON FOUNDATION PLAN
 INDICATING CORNERS WITH NO VERTICAL
 REINFORCEMENT OR CONCRETE POUR.
 5. 28 L/F OF GARAGE WALL WITH NO
 VERTICAL REINFORCEMENT.
 6.NO PRODUCT APPROVAL SHEETS(GARAGE
 DOOR
 PRESSURE SHOWN ON PRINT IS
 38.18,-45.14).
 7. WOULD LIKE TO KNOW WHAT 3,3,6,8, EA.
 END MEANS IN NOTE FOR FORMED & POURED
 CONCRETE BEAMS.
 8. CONTRACTOR SHOWING NO REGISTRATION
 IN
 COMPUTER.
 9. NO REINFORCEMENT SHOWING IN WALL
 SECTION.
 10. NO SITE PLAN SHOWING SETBACKS, WELL
 LOCATION, AND SEWER LOCATION.