Date Text
2005-01-06 11:24:52.00000THE SPACING OF THE PIERS ARE SHOWN AS 7
 FEET 10 INCHES, AND THE MAX. SPACING CAN
 ONLY BE 4FEET 6 INCHES
2005-01-06 11:19:35.00000NEED A COMPLETE SECOND SET OF PLANS. NO
 COPIES WERE MADE.