-     My Account  
   

Log in is not required to search. In the red banner above select: I Want To > Search > Permits

Plan Review Details - Permit 25020234
Plan Review Stops For Permit 25020234
Review Stop BUILDING BUILDING DEPARTMENT
Rev No 4 Status A Date 03-13-2025 Cont ID  
Sent By cdorman Date 03-13-2025 Time 10:03 Rev Time 0.00
Received By cdorman Date 02-26-2025 Time 15:33 Sent To  
Notes
2025-03-14 11:46:39.00000PAYMENT REQUESTED
2025-02-26 15:33:57.00000PERMITS@SUNCORSOLAR.COM

Review Stop BUILDING BUILDING DEPARTMENT
Rev No 3 Status D Date 02-19-2025 Cont ID  
Sent By cdorman Date 02-19-2025 Time 16:24 Rev Time 0.00
Received By cdorman Date 02-19-2025 Time 14:46 Sent To  
Notes
2025-02-19 16:24:37.00000SHEET E1:
 1] INVERTER MAXIMUM AC OUTPUT CURRENT SHOWN IN SUMMARY
 TABLE IS INCORRECT (3.19A VS. 1.21A). THIS AFFECTS ALL
 SUBSEQUENT CALCULATIONS AND VALUES ON THIS SHEET AND ON
 MULTIPLE OTHER SHEETS; CORRECT ALL SHEETS TO CORRESPOND
 TO THE CORRECT INVERTER OUTPUT VALUES.
 2] REVISE THE CONDUIT SIZE BETWEEN THE COMBINER AND PV
 DISCONNECT AND BETWEEN THE PV DISCONNECT AND THE MSP;
 3/4" NOT APPROVED FOR INDICATED CONDUCTORS.
 ALTERNATIVELY, CHANGE CONDUCTOR SIZES TO #6 CU WITH #8
 CU EGC. (SEE ITEM #2 ON SHEET E3 NOTES).
 3] THE SUMMARY TABLE FOR THE MODULES SHOWS INCORRECT
 VALUES FOR THE PROPOSED 410W MODULE; CORRECT TO MATCH
 MANUFACTURER'S SPECIFICATIONS.
  
 SHEET E2: CORRECT PER ITEM #4 LISTED FOR SHEET E1
  
 SHEET E3:
 1] CORRECT PER ITEM #4 LISTED FOR SHEET E1
 2] THE #6 CONDUCTOR SIZE (UPPER LEFT HAND CORNER) IS
 INCONSISTENT WITH THE CONDUCTOR SIZE SHOWN ON SHEET E1.
 (SEE ITEM #2 ON SHEET E1 NOTES).
  
 SHEET E4: SHOW CORRECT COMBINED INVERTER OUTPUT OF
 47.19A ON ALL AC CURRENT LABELS.
  
 MULTIPLE SHEETS: THE "SCOPE OF WORK" TABLE AT THE
 BOTTOM OF THE SHEET SHOWS THE AC & DC OUTPUT VALUES
 REVERSED.
  
  
2025-02-19 14:47:01.00000PERMITS@SUNCORSOLAR.COM

Review Stop BUILDING BUILDING DEPARTMENT
Rev No 2 Status D Date 02-13-2025 Cont ID  
Sent By cdorman Date 02-13-2025 Time 11:15 Rev Time 0.00
Received By cdorman Date 02-12-2025 Time 16:18 Sent To  
Notes
2025-02-13 11:15:28.00000FIRST ITEM OF PREVIOUS REVIEW NOT CORRECTED: ON SHEET
 E-1, SHOW OVERCURRENT PROTECTION IN MAIN PV DISCONNECT
 (SUPPLY-SIDE TAP). REFER TO 705.11 (C), 2020 NEC.
2025-02-12 16:19:04.00000REVISED PLANS
 PERMITS@SUNCORSOLAR.COM

Review Stop BUILDING BUILDING DEPARTMENT
Rev No 1 Status D Date 02-11-2025 Cont ID  
Sent By cdorman Date 02-11-2025 Time 08:38 Rev Time 0.00
Received By cdorman Date 02-07-2025 Time 15:30 Sent To  
Notes
2025-02-11 08:38:23.00000SHEET E-1: SHOW OVERCURRENT PROTECTION IN PV DISCONNECT
 (SUPPLY-SIDE TAP)
 SHEET E-4: SHOW CORRECT SYSTEM OUTPUT CURRENT ON AC
 CURRENT/VOLTAGE LABELS (3 LABELS THIS SHEET)
2025-02-07 15:31:56.00000PERMITS@SUNCORSOLAR.COM