Plan Review Details - Permit 24020108
Plan Review Stops For Permit 24020108
Review Stop BUILDING BUILDING DEPARTMENT
Rev No 1 Status A Date 02-16-2024 Cont ID  
Sent By sarnold Date 02-16-2024 Time 09:50 Rev Time 0.00
Received By sarnold Date 02-05-2024 Time 11:48 Sent To  
Notes
2024-06-17 10:52:32.0000011/02/23 07:59:16 INS ERIC THIS IS A SINGLEWIDE MOBILE
 HOME IN FAIR
 CONDITION. THE FOLLOWING REPAIRS WILL
 NEED TO BE MADE BEFORE FINAL INSPECTION.
 1. SIDING MUST BE REPAIRED TO NOT ALLOW
 WATER INTRUSION.
 2. THE SOFFIT AND FASCIA MUST BE
 REPAIRED/REPLACED.
 3. MINOR INSULATION AND BOTTOM BOARD
 REPAIRS ARE NEEDED IN SMALL AREAS.
 4. THE INTERIOR WALLS NEED TO BE
 REPAIRED TO NOT HAVE HOLES AND ENCLOSE
 WALL CAVITY.
 5. THE EXTERIOR DOOR MUST BE REPLACED.
 6. THERE ARE TWO AREAS THAT ELECTRICAL
 WIRING IS EXPOSED. THESE CONDUCTORS AND
 CONNECTIONS MUST BE REPAIRED TO MEET NEC
 REGULATIONS.
 7. GFCI PROTECTD OUTLETS MUST BE
 INSTALLED IN THE KITCHEN AREA.
 8. THE WATER SUPPLY LINE IS BROKEN AT
 THE WATER HEATER AND MUST BE REPAIRED.
 9. AN EXTERIOR LIGHT IS MISSING AT THE
 SLIDING GLASS DOOR. LIGHT MUST BE
 REPLACED.
 10/27/23 11:31:42 CRE COMPLAINT RECORDED BY ELTHOMPS