Plan Review Details - Permit 23120394
Plan Review Stops For Permit 23120394
Review Stop BUILDING BUILDING DEPARTMENT
Rev No 1 Status A Date 01-02-2024 Cont ID  
Sent By sarnold Date 01-02-2024 Time 10:42 Rev Time 0.00
Received By sarnold Date 12-14-2023 Time 09:00 Sent To  
Notes
2024-06-17 10:40:00.0000012/22/23 16:45:01 INS ERIC THIS IS AN OLDER MODEL
 MOBILE HOME IN
 FAIR CONDITION. THE FOLLOWING ITEMS WILL
 NEED TO BE CORRECTED BEFORE FINAL
 INSPECTION.
 1. THERE IS A CONDUIT ON THE EXTERIOR
 THAT HOUSES ELECTRICAL CONDUCTORS TO
 EXTERIOR LIGHTS.. THIS MUST BE REMOVED.
 2. EXTERIOR ELECTRICAL OUTLETS NEED
 COVERS INSTALLED.
 3. A LIGHT FIXTURE NEEDS TO BE INSTALLED
 AT THE SGD.
 4. THERE IS MINOR INSULATION AND BOTTOM
 BOARD REPAIR NEEDED.
 5. THE ENTRY DOOR FRAME IS ROTTED. FRAME
 MUST BE REPAIRED TO BE WEATHERTIGHT OR
 DOOR REPLACED.
 6. THE SUB−FLOOR IS DAMAGED AT THE ENTRY
 DOOR AND THE SGD. SUB−FLOOR MUST BE
 REPAIRED.
 7. THE HALL BATH SINK DRAIN IS "S"
 TRAPPED. DRAIN MUST BE CORRECTED.
 8. ONE BEDROOM DOOR IS DAMAGED. ALL
 INTERIOR DOORS MUST BE FUNCTIONAL.
 9. THERE IS INTERIOR WALL DAMAGE. ALL
 INTERIOR WALLS MUST BE FREE OG HOLES.
 10. THERE ARE INTERIOR ELECTRICAL
 DEVICES WITHOUT COVERS. ALL DEVICES MUST
 HAVE COVERS.
 11. AN OPERABLE SMOKE DETECTOR MUST BE
 INSTALLED.
 12/14/