-     My Account  
   

Log in is not required to search. In the red banner above select: I Want To > Search > Permits

Plan Review Details - Permit 23100047
Plan Review Stops For Permit 23100047
Review Stop BUILDING BUILDING DEPARTMENT
Rev No 3 Status A Date 11-30-2023 Cont ID  
Sent By cdorman Date 11-30-2023 Time 15:47 Rev Time 0.00
Received By cdorman Date 11-30-2023 Time 15:46 Sent To  
Notes
2023-12-04 09:01:29.00000SENT PAYMENT REQUEST 12/04
2023-11-30 15:46:55.00000REVISED PLAN IS APPROVED BASED ON UPDATED DATA FROM
 SOLAR EDGE. ONLY THE INITIAL PLAN REVIEW FEE PLUS
 PERMIT FEES ARE BEING CHARGED.

Review Stop BUILDING BUILDING DEPARTMENT
Rev No 2 Status D Date 11-20-2023 Cont ID  
Sent By cdorman Date 11-20-2023 Time 16:19 Rev Time 0.00
Received By cdorman Date 10-23-2023 Time 11:51 Sent To  
Notes
2023-11-20 16:18:52.00000REVISED PLANS INDICATE (13) 385W MODULES PER STRING.
 MODULE VOC (NOMINAL OPERATING CELL TEMPERATURE) =
 41.85. 41.85 X 13 = 544 VDC. MAXIMUM INVERTER INPUT
 VOLTAGE = 480 VDC.
 RECONFIGURE SYSTEM TO LIMIT DC INPUT VOLTAGE AT
 INVERTER TO LESS THAN 480 VOLTS PER STRING.
2023-10-23 11:52:10.00000SCGRAY@FREEDOMFOREVER.COM

Review Stop BUILDING BUILDING DEPARTMENT
Rev No 1 Status D Date   Cont ID  
Sent By   Date 10-19-2023 Time   Rev Time 0.00
Received By cshackel Date 10-03-2023 Time 10:39 Sent To  
Notes
2023-10-12 14:09:20.00000SHEET PV-4: MAXIMUM SERIES VOC ON STRING #1 EXCEEDS
 MAXIMUM DC INPUT VOLTAGE OF INVERTER. 15 MODULES @
 41.85VOC > 480VDC INVERTER MAXIMUM.
2023-10-10 12:31:40.00000ALREADY PAID FOR PERMIT THE RECEIPT IS 9177250 236.78
 SEE ATTACHMENT
2023-10-03 10:39:26.00000SCGRAY@FREEDOMFOREVER.COM

Copyright © 2008 – THE PLUS SERIES ® – All Rights Reserved