Plan Review Stops For Permit 22080382
Review Stop BUILDING BUILDING DEPARTMENT
Rev No 2 Status A Date 09-06-2022 Cont ID  
Sent By cdorman Date 09-06-2022 Time 15:49 Rev Time 0.00
Received By cdorman Date 08-17-2022 Time 16:48 Sent To  
Notes
2022-08-17 16:49:04.00000REVISED PLANS JWILSON@URBANSOLAR.COM

Review Stop BUILDING BUILDING DEPARTMENT
Rev No 1 Status D Date 08-09-2022 Cont ID  
Sent By cdorman Date 08-09-2022 Time 17:10 Rev Time 0.00
Received By cdorman Date 08-07-2022 Time 09:28 Sent To  
Notes
2022-08-09 17:10:22.00000SHEET PV-3: INCREASE CONDUCTORS IDENTIFIED AS #5 AND #6
 TO MINIMUM #3 COPPER. THESE CONDUCTORS DO NOT SUPPLY
 THE ENTIRE DWELLING UNIT AND THEREFORE ARE NOT SUBJECT
 TO DERATING PER 310.15 (B)(7).
  
 OTHER: AN ATTACHED ELECTRICAL PERMIT IS REQUIRED FOR
 ISSUANCE OF THIS SOLAR PERMIT; THE SCOPE OF WORK
 EXTENDS BEYOND A SIMPLE INTERCONNECTION OF THE PV
 SYSTEM.
2022-08-07 09:29:17.00000JWILSON@URBANSOLAR.COM