-     My Account  
   

Log in is not required to search. In the red banner above select: I Want To > Search > Permits

Plan Review Details - Permit 22060745
Plan Review Stops For Permit 22060745
Review Stop BUILDING BUILDING DEPARTMENT
Rev No 2 Status A Date 08-10-2022 Cont ID  
Sent By cdorman Date 08-10-2022 Time 08:19 Rev Time 0.00
Received By cdorman Date 07-22-2022 Time 09:42 Sent To  
Notes
2022-07-22 09:42:31.00000REVISED PLANS APRIL.SHEDLOCK@MERAKISOLUTIONS.COM

Review Stop BUILDING BUILDING DEPARTMENT
Rev No 1 Status D Date 06-13-2022 Cont ID  
Sent By cdorman Date 06-13-2022 Time 13:12 Rev Time 0.00
Received By cdorman Date 06-10-2022 Time 15:45 Sent To  
Notes
2022-06-13 13:12:08.000001] SHEET PV05: CONDUCTORS #4 AND #5 INCORRECT. MINIMUM
 AMPACITY = 83.3. USE #4 CU WITH 90A FUSES OR #3 CU WITH
 100A FUSES.
 2] SHEET PV07: SHOW ADDITIONAL AC CURRENT LABEL
 INDICATING TOTAL SYSTEM OUTPUT (COMBINED EXISTING PLUS
 PROPOSED SYSTEM OUTPUT).
2022-06-10 15:45:32.00000PERMITTINGCENTRAL@MERAKISOLUTIONS.COM