Review Stop BUILDING BUILDING DEPARTMENT
Rev No 2 Status A Date 08-04-2020 Cont ID  
Sent By cdorman Date 08-04-2020 Time 15:18 Rev Time 0.00
Received By cdorman Date 08-04-2020 Time 15:18 Sent To  
Notes
2020-08-04 15:18:44.00000REVISED RISER DIAGRAM REC'D WITH CORRECTIONS.

Review Stop BUILDING BUILDING DEPARTMENT
Rev No 1 Status D Date 07-29-2020 Cont ID  
Sent By cdorman Date 07-29-2020 Time 16:01 Rev Time 0.00
Received By cdorman Date 07-29-2020 Time 08:40 Sent To  
Notes
2020-07-29 16:01:17.000001] SPECIFY EXACT MICROINVERTER TO BE USED, I.E.,
 IQ7-60-2 OR IQ7PLUS-72-2
 2] ON RISER DIAGRAM, OPERATING CURRENT LABELS (20 AMPS)
 DOES NOT MATCH INVERTER OUTPUT CURRENT OF 14 X 1 AMP.