Plan Review Stops For Permit 20060352
Review Stop BUILDING BUILDING DEPARTMENT
Rev No 3 Status A Date 07-17-2020 Cont ID  
Sent By cdorman Date 07-17-2020 Time 15:30 Rev Time 0.00
Received By cdorman Date 07-17-2020 Time 08:10 Sent To  
Notes
2020-07-17 15:30:54.00000REVISED ROOF LAYOUT APPROVED.
2020-07-17 08:11:29.00000REVISED PLANS 07/17/20

Review Stop BUILDING BUILDING DEPARTMENT
Rev No 2 Status D Date 07-07-2020 Cont ID  
Sent By cdorman Date 07-07-2020 Time 08:47 Rev Time 0.00
Received By cdorman Date 07-06-2020 Time 16:26 Sent To  
Notes
2020-07-07 08:47:36.00000REVISED PLAN DOES NOT COMPLY WITH FLORIDA FIRE
 PREVENTION CODE 11.12.2.2.2.
 MINIMUM 3 FT SEPARATION FROM RIDGE IS REQUIRED (ROOF R1
 & R2).
 MINIMUM 1.5 FT SEPARATION FROM VALLEY IS REQUIRED WHERE
 MODULES ARE LOCATED ON BOTH SIDES OF THE VALLEY (CORNER
 OF ROOFS R1 & R2)
2020-07-06 16:27:09.00000REVISION RECEIVED IN MAIL

Review Stop BUILDING BUILDING DEPARTMENT
Rev No 1 Status A Date 06-16-2020 Cont ID  
Sent By cdorman Date 06-16-2020 Time 14:51 Rev Time 0.00
Received By cdorman Date 06-16-2020 Time 08:25 Sent To  
Notes
***NONE***