-     My Account  
   

Log in is not required to search. In the red banner above select: I Want To > Search > Permits

Plan Review Details - Permit 19120373
Plan Review Stops For Permit 19120373
Review Stop BUILDING BUILDING DEPARTMENT
Rev No 1 Status A Date 02-24-2020 Cont ID  
Sent By elongsho Date 02-24-2020 Time 09:58 Rev Time 0.00
Received By elongsho Date 12-19-2019 Time 10:08 Sent To  
Notes
2019-12-19 10:09:11.00000THREE (3) SET OF PLANS SUBMITTED FOR REVIEW, TWO (2)
 FORWARD TO COUNTY FIRE FOR REVIEW CARRIER ERIC
 LONGSHORE.
  

Review Stop ETRANSPCON TRANSPORTATION CONCURRENCY
Rev No 1 Status X Date 02-24-2020 Cont ID  
Sent By elongsho Date 02-24-2020 Time 09:58 Rev Time  
Received By elongsho Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status A Date 02-24-2020 Cont ID  
Sent By cshackel Date 02-24-2020 Time 10:01 Rev Time 0.00
Received By cshackel Date 02-24-2020 Time 10:00 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status D Date 01-17-2020 Cont ID  
Sent By hlopez Date 01-17-2020 Time 08:30 Rev Time 0.00
Received By hlopez Date 12-19-2019 Time 10:09 Sent To  
Notes
2020-01-17 08:31:20.00000MEMORANDUM
 TO: ERIC LONGSHORE, BUILDING OFFICIAL
 FROM: JAMES E. BRANCA, SR., BATTALION CHIEF, FIRE
 MARSHAL
 DATE: JANUARY 17, 2020
 RE: ALL ABOUT LAWNS INC., PERMIT # 19120373
 THESE PLANS WERE REVIEWED FOR COMPLIANCE WITH THE
 FLORIDA FIRE PREVENTION CODE, SIXTH EDITION. ALL
 REFERENCES TO NFPA 1 OR NFPA 101 WITHIN THIS CODE SHALL
 BE THE FLORIDA SPECIFIC VERSION OF NFPA 1 AND NFPA 101.
 THE FOLLOWING ISSUES NEEDING TO BE ADDRESSED:
 1. SEPARATION BETWEEN OCCUPANCIES. THERE IS A STORAGE
 OCCUPANCY ON THE SECOND FLOOR, AND A MERCANTILE,
 BUSINESS, AND INDUSTRIAL OCCUPANCY ON THE FIRST FLOOR.
 (NFPA 101, 6.1.14)
 2. THE STORAGE OCCUPANCY NEEDS TO DEPICT AN ORGANIZED
 STORAGE ARRANGEMENT. (NFPA 1, 10.18)
 3. THE MERCANTILE, STORAGE, AND INDUSTRIAL OCCUPANCIES
 NEED TO CLASSIFY THE HAZARD OF CONTENTS. (NFPA 101,
 36.1.5), (NFPA 101, 40.1.5), AND (NFPA 101, 42.1.5)
 4. UNABLE TO DETERMINE STAIR DETAILS SUCH AS RISER
 HEIGHT, TREAD DEPTH, HEADROOM CLEARANCE, AND HANDRAILS.
 (NFPA 1, 1.14)
 5. UNABLE TO DEPICT MEASUREMENTS FOR THE SECOND FLOOR
 TO DETERMINE CODE COMPLIANCE. (NFPA 1, 1.14)
 6. THE SHOWROOM NEEDS A SECOND MEANS OF EGRESS. (NFPA
 101, 36.2.4)
 7. SECOND FLOOR NEEDS EMERGENCY LIGHTING AND AN EXIT
 LIGHT. (NFPA 101, 36.2.9 AND 36.2.10)
 8. PLEASE NOTE ANY PROPOSED FIRE BARRIERS WILL REQUIRE
 A UL DESIGN AND MUST INCLUDE PROTECTION FOR OPENINGS
 AND PENETRATIONS. (NFPA 101, 8.3)
 I AM RETURNING THESE DRAWINGS TO YOUR OFFICE WITHOUT
 FIRE CODE APPROVAL. PLEASE HAVE THE ENGINEER OF RECORD
 ADDRESS THESE FINDINGS.
 ALSO, ADDRESSING THESE ISSUES MAY SPUR FURTHER FIRE
 CODE REQUIREMENTS. THAT SAID, I WOULD BE WILLING TO
 MEET WITH THE APPLICANT TO HELP THEM STREAMLINE
 COMPLIANCE.