Plan Review Details - Permit 19100620
Plan Review Stops For Permit 19100620
Review Stop BUILDING BUILDING DEPARTMENT
Rev No 1 Status C Date 10-31-2019 Cont ID HC04151
Sent By cdorman Date 10-31-2019 Time 15:51 Rev Time 0.00
Received By cdorman Date 10-30-2019 Time 11:32 Sent To  
Notes
2019-10-31 15:54:10.00000APPROVED CONDITIONALLY; COMPLIANCE WITH THE FOLLOWING
 NOTES REQUIRED:
 1] METAL RACEWAYS ON LINE SIDE OF PV AC DISCONNECT MUST
 BE BONDED (BONDING BUSHING, ETC)
 2] PANELS MUST MAINTAIN MINIMUM 3 FOOT CLEARANCE BELOW
 ROOF RIDGE IN COMPLIANCE WITH FLORIDA FIRE PREVENTION
 CODE
 3] COMPLY WITH RAPID SHUTDOWN REQUIREMENTS PER NEC
 690.12 AND AFFIX COMPLIANCE LABEL AT PV AC DISCONNECT
 OR INVERTER