-     My Account  
   

Log in is not required to search. In the red banner above select: I Want To > Search > Permits

Inspection Details
INSPECTION DETAILS FOR PERMIT 15100351
Permit Number 15100351 Owner Name GROVES DON E + VIRGINIA E TRS
Permit Type SOLAR Permit Address 3213 SPARKLING DR
Inspection Type FINAL-1 City/State/Zip SEBRING, FL 33870
Inspect Area SE Inspector CHUCK
Request Date 11-10-2015 Scheduled Date 11-12-2015
Instructions  
Contact Info  
Contractor   Inspect Date 11-12-2015
Result F Fail Code  
Comments  
Work Time   Confirmation Number 144979
Fee ID BRI
Inspector Notes
Date Text
2015-11-13 08:18:01.000001] IMPROPER CONDUCTOR TERMINATION ON LOWER RIGHT LUG
 IN SAFETY SWITCH.
 2] NO GROUNDING ELECTRODE SYSTEM PER 690.47.