INSPECTION DETAILS FOR PERMIT 24020877
Permit Number 24020877 Owner Name KING NELSON + DEBORAH
Permit Type BRNBLMONO Permit Address 4043 SANTA BARBARA DR
Inspection Type PRE-POWER ELECTRIC-5 City/State/Zip SEBRING, FL 33875
Inspect Area   Inspector CHUCK
Request Date 06-18-2024 Scheduled Date 06-20-2024
Instructions  
Contact Info  
Contractor HC05706 Inspect Date 06-20-2024
Result F Fail Code  
Comments  
Work Time   Confirmation Number 7383001
Fee ID BRI
Inspector Notes
Date Text
2024-06-20 12:17:51.000001] REPLACE OR REPAIR PANEL COVER (DEADFRONT RETAINER
 MISSING)
 2] USE LONGER MACHINE SCREWS TO SECURE PANEL COVER (DO
 NOT USE SHEET METAL SCREWS)
 3] USE ALL COVER SCREWS IN MICROWAVE OUTLET.
 COVER-MOUNTED RECEPTACLE CANNOT BE SECURED BY A SINGLE
 SCREW.
 4] CORRECT PANEL LABELING (CIRC 1/3 IS DRYER, CIRC 5/7
 IS WATER HEATER). NOTE THIS ITEM WAS OVERLOOKED ON RT;
 OK FOR FINAL INSPECTOR TO WRITE IN ON PANEL LABEL.