INSPECTION DETAILS FOR PERMIT 22030551
Permit Number 22030551 Owner Name FRANK CHESTER WILLIAM III
Permit Type BRNBLMONO Permit Address 917 WATERWAY TER
Inspection Type PRE-POWER ELECTRIC-3 City/State/Zip LAKE PLACID, FL 33852
Inspect Area LP Inspector JOHNK
Request Date 05-13-2024 Scheduled Date 05-14-2024
Instructions  
Contact Info  
Contractor OWNER Inspect Date 05-14-2024
Result P Fail Code  
Comments DUKE ENERGY OK POWER 10:34 PM CAS
Work Time   Confirmation Number 7380650
Fee ID  
Inspector Notes
Date Text
2024-05-14 15:05:03.00000THE "FRIDGE", "PANTRY FRIDGE", AND "FIREPLACE" CIRCUITS
 (RESPECTIVELY CIRCUIT #23, #25, & #27) REQUIRE AFCI
 PROTECTION.
 * CORRECT THE ABOVE BY FINAL.
 ** THERE ARE CIRCUIT BREAKERS ON OTHER CIRCUITS THAT
 COULD BE SWAPPED WITH THE GFCI CIRCUIT BREAKERS FEEDING
 THE ABOVE CIRCUITS.