-     My Account  
   

Log in is not required to search. In the red banner above select: I Want To > Search > Permits

Inspection Details
INSPECTION DETAILS FOR PERMIT 04040155
Permit Number 04040155 Owner Name WINBERRY J LEE
Permit Type BRNBLMONO Permit Address 3604 CREEKSIDE DR
Inspection Type PRE LATH-3 City/State/Zip SEBRING, FL 33875-
Inspect Area SE Inspector ARNOLD
Request Date 09-21-2005 Scheduled Date 09-22-2005
Instructions  
Contact Info  
Contractor 173-01 Inspect Date 09-22-2005
Result P Fail Code  
Comments  
Work Time   Confirmation Number 24252
Fee ID  
Inspector Notes
Date Text
2005-09-22 10:36:25.00000BPL:9/22/05 RED TAG: TRUSSES V-9, V9A,
 V9B, B9C, P-1,P-2,02 THRU 06 AND N-1 ALL
 NEED LAYERS, E1, E2 AND E3 TRUSSESS NOT
 STRAPPED, D-5 GIRDER NEEDS CONNECTOR
 3607 UPLIFT, ALL LATERAL BRACING MUST
 CONTINUE TO NEXT TRUSS, SEE TRUSS
 SHEETS, TRUSSES B-9, C-1 AND C-2 MISSING
 LATERAL BRACE, TRUSS A-1 MISSING STRAP,
 FIREBLOCK TOP OF FIREPLACE AND MASTER
 BATH WALL AT SINK, VALLEY SET STRAPS NOT
 NAILED ABOVE MASTER BATH, NO VALLEY SET
 STRAPS ABOVE FRONT ENTRANCE , SEAL TOP
 PLATE AT DRYER VENT ARE OLD CUT-OUT
Copyright © 2008 – THE PLUS SERIES ® – All Rights Reserved