INSPECTION DETAILS FOR PERMIT 19070686
Permit Number 19070686 Owner Name WILSON MARCIA R +
Permit Type BRNBLMONO Permit Address 6404 APPLE RD
Inspection Type PRE-POWER ELECTRIC-1 City/State/Zip SEBRING, FL 33875
Inspect Area SE Inspector CHUCK
Request Date 12-12-2019 Scheduled Date 12-13-2019
Instructions  
Contact Info  
Contractor 764-01 Inspect Date 12-13-2019
Result F Fail Code  
Comments  
Work Time   Confirmation Number 7276719
Fee ID  
Inspector Notes
Date Text
2019-12-13 14:35:52.000001] INSTALL ADDRESS NUMBERS ON HOUSE
 2] BOND TRANSFER SWITCH TO NEUTRAL (MISSING BONDING
 SCREW)
 3] REMOVE NEUTRAL CROSSOVER BAR IN GARAGE PANEL AND
 INSTALL BONDING SCREW ON EQUIPMENT GROUND BAR. REMOVE
 BONDING SCREW ON NEUTRAL BAR.
 4] NM CABLE SHEATH IS NOT FULLY ENTERED INTO KITCHEN
 ISLAND JUNCTION BOX; REWORK CABLES AS REQUIRED.
 CHECK HVAC BREAKER SIZES AT FINAL.