2020-11-30 14:14:32.00000ELEC ROUGH: 1] ADD SMOKE/CO DETECTOR NO MORE THAN TEN
 FEET FROM BACK BEDROOM DOOR
 2] AT ALL THREE SMALL BEDROOMS, CABLE SHEATH MUST FULLY
 ENTER EACH SMOKE DETECTOR BOX
 3] IN ROOM IN FRONT OF KITCHEN, BOX WITH THREE 12/2
 CABLES IS OVERFILLED, MUST BE REPLACED
 4] SECURE 2-GANG SWITCH BOX IN FRONT BEDROOM.