-     My Account  
   

Log in is not required to search. In the red banner above select: I Want To > Search > Permits

Inspection Details
INSPECTION DETAILS FOR PERMIT 12030074
Permit Number 12030074 Owner Name ARTHUR MARK + SANDY
Permit Type BRNBLMONO Permit Address 4516 VANTAGE CIR
Inspection Type PRE LATH-1 City/State/Zip SEBRING, FL 33872
Inspect Area SE Inspector RFS
Request Date 05-14-2012 Scheduled Date 05-15-2012
Instructions  
Contact Info  
Contractor   Inspect Date 05-15-2012
Result F Fail Code N
Comments SEE NOTES
Work Time   Confirmation Number 121149
Fee ID BRI
Inspector Notes
Date Text
2012-05-15 12:35:27.000001) LATERAL BRACING ON 6-A9 TRUSSES SHOULD BE ON WEB
 MEMBER W9 NOT W8.
 2) META20 TRUSS STRAP ONLY COVERS 1450 LBS UPLIFT. A1
 MID-POINT BEARING HAS 1640 LBS UPLIFT.
 ADD ANOTHER ANCHOR.
 3) TUB DRAIN AND OVERFLOW HAS NOT BEEN COMPLETED.
Copyright © 2008 – THE PLUS SERIES ® – All Rights Reserved