Date Text
2008-01-10 13:37:46.000001)TRUSS HANGERS MISSED ON F1 TRUSSES &
 1X4 T-BRACE ON A21 TRUSS NEDDS TO BE 2X4
 T-BRACE. 2)FIREBLOCK SOFFITS IN M. BATH.
 3)SWAP TEMP GLASS WINDOW IN M. BATH
 COMMODE ROOM W/UNTEMP GLASS IN GUEST
 BATH. 4)FIREBLOCK ARCH GOING TO
 KITCHEN-DINETTE AREA. 5)CAP WIRE CHASE
 IN KITCHEN BY ARCH. 6)FIREBLOCK KITCHEN
 PANTRY @ CEILING CHANGE. 7)FIX EXTRA
 DRYER VENT HOLES IN LAUNDRY WALL.
 8)TUFF-R SEAMS NEED TO BE TAPED. 9)FOAM
 AROUND ELECTRIC BOXES ON EXTERIOR WALLS.
 10)FOAM LARGE CRACKS IN CHASE CAP OF
 TRIANGULAR SPACE @ HALL GOING TO M.
 BEDROOM. 11)FOAM A/C LINES @ TOP PLATE
 IN M. BEDROOM CLOSET. 12)DRAFT STOP 2X4
 SUPPORTS @ POOL BATH SOFFITS. 13)FINISH
 BLOCKING 12' KITCHEN WALL.