-     My Account  
   

Log in is not required to search. In the red banner above select: I Want To > Search > Permits

Inspection Details
INSPECTION DETAILS FOR PERMIT 02120483
Permit Number 02120483 Owner Name BEAN FRANK + MARY ELLEN
Permit Type BRNBLMONO Permit Address 4660 CALLAWAY GARDENS DR
Inspection Type PRE LATH-1 City/State/Zip SEBRING, FL 33872
Inspect Area AP Inspector ARNOLD
Request Date 02-11-2003 Scheduled Date 02-12-2003
Instructions  
Contact Info  
Contractor 764-01 Inspect Date 02-12-2003
Result F Fail Code  
Comments A-18 HIP SET NOT STRAPPED AT BEARING
Work Time   Confirmation Number 5571078
Fee ID BRI
Inspector Notes
Date Text
2003-02-12 16:25:50.00000BPL:RED TAG:WALL PER DETAIL (D) ON PLAN,
 TRUSSES A-8, 1 IS MISSING T-BRACE AND 1
 IS BROKEN, NEED ENG OK FOR REPAIR, TRUSS
 A-12 T-BRACE IN WRONG LOCATION, GIRDER
 C-1 NOT STRAPPED PER DETAIL (B) DETAIL
 B HAS WRONG UPLIFTS, TRUSS A-14 MISSING
 T-BRACE, REPAIR FIREBLOCKING AT RANGE
 VENT, SLIDING GLASS DOOR SCREWS MUST BE
 ALL TAPCONS, EXTERIOR DOORS ARE MISSING
 TAP CONS IN THRESHOLDS, INSTALL NAIL
 PLATES OVER VENT PIPE IN MASTER BATH
Copyright © 2008 – THE PLUS SERIES ® – All Rights Reserved