Result F Fail Code  
Comments SEE NOTES
Work Time   Confirmation Number 7269963
Fee ID  
Inspector Notes
Date Text
2019-06-26 14:54:28.000001). REPLACE BROKEN GLASS IN REAR BEDROOM.
 2). ADD RECEPT. IN GARAGE, ONE REQ'D FOR EACH CAR SPACE
 210.52G
 3). CHANGE RANGE BRKR TO 40A (#8 NM).
 4). CHANGE AIR HANDLER BRKR TO 30A (5KW).
 5). SMOKE DETECTOR IN GUEST BATH HALLWAY MUST BE
 SMOKE/CARBON MONOXIDE.
 6). DO NOT USE SHEET METAL SCREWS ON PANEL COVER.
 7). MARK AIR HANDLER WITH INSTALLED HEAT SIZE
 (INSPECTOR HAS FIELD CONFIRMED).
 8). REPLACE CAPS AT AC UNIT WITH LOCKING TYPE.