Date Text
2018-04-11 15:42:08.00000ROOF NOT COMPLETE ON FRONT WHERE CARPORT AND FAMILYU
 ROOM ARE TO BE REPLACED. ROOFER ADDED VERY THIN
 GALVANIZED FLASHING ALONG ENTIRE LENGTH OF FRONT, BUT
 NEVER ADDED DRIPEDGE BEFORE DOING SO. AN ATTEMPT WAS
 MADE ON 4/10/18 TO ADD DRIP, BUT ONLY TWO PIECES HAD
 BEEN ADDED AT TIME OF INSPECTION. OWNER TOLD ME THAT HE
 HAD ABOUT 6" OF FLASHING CUT OFF BECAUSXE THE WIND WAS
 RAISING HIS SHINGLES AND RUINING THEM. ROOM AND CARPORT
 ARE NOT GOING TO BE ADDED UNTIL AUGUST ACCORDING TO
 OWNER. I BELIEVE THAT SHINGLES SHOULD BE REMOVED ENOUGH
 TO ALLOW PEEL & STICK TO BE ADDED AT EAVE, THEN
 SHINGLES PUT BACK ON, BUT LEFT UP FROM EAVE ABOUT 1'-0"
 UNTIL ROOMS ARE ADDED, THEN FINISH ROOF.