INSPECTION DETAILS FOR PERMIT 22101197
Permit Number 22101197 Owner Name ZEPHYR HOMES LLC
Permit Type BRNDUP Permit Address 6025 RED CEDAR RD
Inspection Type FRAMING-1 City/State/Zip SEBRING, FL 33876
Inspect Area   Inspector ERIC
Request Date 02-22-2023 Scheduled Date 02-23-2023
Instructions  
Contact Info  
Contractor HC03661 Inspect Date 02-23-2023
Result F Fail Code  
Comments SEE NOTES
Work Time   Confirmation Number 7347953
Fee ID  
Inspector Notes
Date Text
2023-02-23 16:48:16.00000TRUSS 1G WILL NEED A MGT ANCHOR. (2 TOTAL)
 TRUSSES 3A AND 3B ARE MISSING BRACING. (BOTH SIDES)
 TRUSSES 2 ABC&D SHOW AN INTERIOR BEARING POINT. THIS
 WALL IS NOT BUILT AS A BEARING WALL. ENGINEER OF RECORD
 WILL NEED TO APPROVE.
 THE BEARING WALL IN THE GARAGE IS CANTALEVERED OVER THE
 CONCRETE SLAB. ANCHORING OF THIS WALL SECTION WILL NEED
 TO BE APPROVED BY THE ENGINEER OF RECORD.
 I MET CONTRACTOR ONSITE TO EXPLAIN AND HE WILL GET THE
 ENGINEER OF RECORD TO INSPECT AND PROVIDE A REPORT.