-     My Account  
   

Log in is not required to search. In the red banner above select: I Want To > Search > Permits

Code Enforcement Detail
Code Enforcement Detail
Case Number CE25070059 complainant JOHN O'SULLIVAN
Case Date 07-11-2025 address 225 LAKESIDE RD
Origination WALKN - WALK IN Status C - CLOSED
Operator bsingley Officer SHC
Fines Balance $0.00
Lien Balance $0.00
Total Balance $0.00
Property On Case
STRAP NBR C-25-34-28-030-4270-0130 Owner PONS NELSON ALEJANDRO OTI +
Unit   Owner Address 231 LAKESIDE RD
Property Address 231 LAKESIDE RD City/State/Zip SEBRING FL 33870
City/State/Zip SEBRING FL 33870 Phone  
Case Description
CARPORT CLOSED IN AS ROOM WITH KITCHEN, AND OWNERS
MAYBE RENTING OUT AS SEPARATE UNIT, ELECTRICAL
PANEL SEPARATE AND MAY NOT BE UP TO CODE
CE REVIEWED WITH ZONING/AK/MC OWNER WILL NEED TO
SIGN A FORM, NOW WITH TWO KITCHENS THIS HOME WOULD
STILL BE A SINGLE FAMILY HOME. ZONING WILL MAIL
OWNERS COPY OF FORM TO SIGN AND RETURN. BSS
COMPLAINT FOR RUN OFF OF WASHING MACHINE ONTO
GROUND, AND SEPTIC NOT BIG ENOUGH, REFERRED
COMPLAINANT TO HEALTH DEPT
CE ADMIN/SUPERVISOR ASKING FOR SHC INSPECTOR AND
CEO FOR YARD WASTE TO INSPECT TOGETHER AND TAKE
PICTURES FOR CASE, REPORT BACK TO HER
Complaint Code(s)
1: MAINT OF BLDGS,STRUCT/PREMISE
Inspections/Events Detail
DATETIMEINSPECTION / EVENT TYPEINSTRUCTIONS / COMMENTS
08-28-202508:31 AMCLOSE COMPLAINTCASE CLOSED BY ASHAFFER
08-27-202511:10 AMREINSPECTIONELECTRICAL ITEMS NOTED ON 8/11/25
INSPECTION HAVE BEEN COMPLETED TO A
SATISFACTORY LEVEL OF SAFETY.
08-27-202508:29 AMREINSPECTION08-27-2025 (SEE NOTES FROM CD)CEO MADE
SITE VISIT WITH CD ALL VIOLATIONS ON SHC
CASE HAVE BEEN COMPLIED CEO CLOSING CASE
AS/CD 1 HR
08-26-202509:34 AMUPDATE/NOTES08-26-2025 AS/YC CALLED TO SET UP
INSPECTION OF THE DWELLING AND SET
APPOINTMENT FOR 08-27-2025 AT 9 AM SHE
AGREED. AS/YC 15 MIN
08-19-202511:13 AMUPDATE/NOTES08-18-2025 RECIEVED COMPLAINT
INVESTIGATION REPORT FROM DOH THEY WILL
BE HANDLING THE INVESTIGATION OF THE
WASHER RUNNING ONTO THE GROUND NOT
PROPERLY ATTACHED TO SEPTIC SYSTEM AS 15
MIN
08-11-202502:58 PMREINSPECTION08-11-2025 AS/CD MADE SITE VISIT THE
INTERIOR INSPECTION SHOWED THAT THE DOOR
WAY HAS BEEN CLEARED AND YOU CAN ACCESS
THE OTHER ROOM FROM INSIDE NOW AND CEO
ASKED IF THE OTHER TENANT WAS RELATED TO
THEM HE STATED IT WAS ALL ONE FAMILY
STAYING IN THE HOME THE WASHING MACHINE
IS UNPLUGED HOWEVER THE DRAIN IS STILL
ON THE GROUND NOT CONNECTED TO ANY
SEPTIC OR SEWER SEE NOTES FROM CD FOR
THE ELECTRICAL REQUIREMENTS CEO WILL
REVIEW WITH STAFF FOR FURTHER DIRRECTION
AS/CD 1 HR
08-11-202502:54 PMREINSPECTIONMINIMUM ELECTRICAL CORRECTIONS REQ'D:
1] IN UNIT 1 INTERIOR PANEL, REPLACE
BRKRS LABELED "OVEN" & "STOVE" TO 30A TO
MATCH CONDUCTOR AMPACITY.
2] AT METER/MAIN, INSTALL NEW DEADFRONT
IF AVAILABLE; REPLACE 3 MINI-SPLIT BRKRS
WITH 15A; INSTALL EXPOSED UF CABLE IN
CONDUIT UP TO 8 FT ABOVE GRADE
3] PANEL ADJACENT TO METER-MAIN IS AN
INDOOR ENCLOSURE, HAS OPEN DEADFRONT
SPACES, ITS FEEDER PROTECTION IS
INCORRECT, AND IT IS NOT GROUNDED. ONLY
A DRYER CIRCUIT IS SUPPLIED. RECOMMEND
RELOCATING DRYER CIRCUIT TO METER-MAIN
AND REMOVING THIS PANEL.
4] FOR 3 MINI-SPLIT UNITS, PROTECT ALL
CIRCUIT CONDUCTORS WITH CONDUIT WHERE
WITHIN 8 FT OF GRADE; REPLACE RECEPTACLE
COVERS WITH IN-USE TYPE. WILL ACCEPT
EXISTING PLUG-AND-CORD CONNECTIONS AS
DISCONNECTING MEANS.
5] NO DEFICIENCIES NOTED IN APT. UNIT #2
08-11-202508:41 AMUPDATE/NOTES08/11/25 - RESPONDENT CALLED BACK AND
SPOKE WITH STAFF ABOUT THE INSPECTION
THAT IS SCHEDULED FOR TODAY. A.H. FROM
BUILDING TRANSLATED. -ELW
08-11-202508:27 AMUPDATE/NOTES08-11-2025 AS/AK CALLED RESPONDENT AND
LEFT VM FORTHEM TO CALL BACK SO CEO CAN
MAKE INSPECTION AS/AK 15 MIN
08-06-202501:59 PMUPDATE/NOTES08/06/25 - COMPLAINANT CALLED IN AND
SAID THERE ARE NEW TENANTS THAT HAVE
MOVED IN. -ELW
07-29-202509:07 AMUPDATE/NOTES07/29/25 MELISSA H. OF FDOH LEFT VM FOR
CEO (863)267-5505. SHE DID TAKE PICTURES
OF THE WASHER OUTSIDE. AND WILL BE
SENDING A LETTER TO THE HOMEOWNER. SHE
ASKED FOR CEO TO CALL HER TO GET EMAIL
OF LETTER AND PICTURES. - ELW
07-28-202510:19 AMUPDATE/NOTES7-28-2025 SENT PHOTOS AND HISTORY OF
CASE TO OWNERS EMAIL
MELANY.2985@YAHOO.ES JD 45 MIN
07-28-202510:00 AMUPDATE/NOTES7-28-2025 SENT EMAIL TO HEALTH DEPT.
WITH PHOTOS OF WASHING MACHINE, ASKING
FOR THEIR ASSISTANCE WITH A
LETTER/INSPECTION. JD 30 MIN
07-25-202509:51 AMUPDATE/NOTES7-25-2025 AK, AS, AND JD RETURNED CALL
TO OWNERS, AK SPOKE WITH THEM AND
TRANSLATED FOR STAFF. SHE INFORMED THE
OWNERS THAT WE ARE AWARE THAT THE
TENANTS ARE NOT RELATED PURSUANT TO
CONVERSTATION WITH THE TENANTS VIA A.S.
THEY REQEUSTED PHOTOS, AND OTHER
INFORMATION BE SENT VIA EMAIL.
MELANY.2985@YAHOO.ES. CE JD WILL FORWARD
THIS ONTO THEM. JD/AS/AK 30 MIN
07-23-202512:47 PMUPDATE/NOTES07/23/25 - MAYELIN CALLED IN TO GO OVER
THE WC (305)879-3066. REQUESTING A CALL
BACK FROM CEO. - ELW
07-23-202511:53 AMREINSPECTION7-23-2025 POSTED WC25070059A TO NEISON
ALEJANDRO OTI PONS AND MAYLIN ALIUSKA
MONTALVO TEIJEIRO FOR 12.05.210(RA1
ZONING), 12.16.101(OCCUPIED) AND
12.03.101(BLDG. PERMITS REQUIRED) GAVE
UNTIL 8-22-2025 TO PULL ALL OF THE
NECESSARY PERMITS TO CONVERT DUPLEX BACK
TO SFR. 7-23-2025 MAIL CERT/REG MAIL,
7-24 POST TO CEB. JD 2 HOUR
07-16-202512:05 PMUPDATE/NOTES07-16-2025 OWNER CALLED IN AS/YC SPOKE
WITH HER SHE STATED IF CEO NEEDS TO SEE
INTERIOR OF THE SECOND APARTMENT SHE
WILL PERSONALLY BE THERE IF NEEDED YC
EXPLAINED AS OF RIGHT NOW THEY DO NOT
NEED TO SEE INSIDE BUT IN THE FUTURE
THEY MAY NEED TO CEO STATED HE WILL CALL
AHEAD IF INSPECTION IS NEEDED AS/YC 15
MIN
07-16-202512:01 PMINITIAL INSPECTION07-16-2025 AS/CD MADE SITE VISIT WAS
GRANTED ENTRY BY TENANT IN APARTMENT 1
WHO CONFIRMED SHE IS RENTING AND WAS NOT
RELATED TO THE RENTERS IN THE SECOND
UNIT THE OWNERS HAVE SEALED THE DOOR
THAT SEPERATED THE TWO UNITS AND HAVE
DONE ELECTRICAL WORK AND WORK ON THE
DWELLING WITH OUT PULLING ANY OF THE
PROPER PERMITING, THERE ARE WASHING
MACHINES (2) OUTSIDE THE DWELLING THAT
THE WASTE WATER IS FLOWING ONTO THE
GROUND, CD TO PUT IN FULL REPORT ON
FINDINGS FOR THE ELECTRICAL, MADE
CONTACT WITH TENANT OF SECOND APARTMENT
AND WAS DENIED ENTRY TO MAKE
INSPECTIONS, CEO WILL REVIEW WITH STAFF
AND COLLECT ALL FINDINGS FROM BUILDING
DEPARTMENT AND POST PROPERTY AT A LATER
DATE AS/CD 2 HRS
07-16-202509:59 AMREINSPECTIONUNKNOWN IF ANY INTERIOR WIRING WAS
INSTALLED/ALTERED; BLDG. IS CURRENTLY IN
FINISHED CONDITION.

UNIT #1: TWO 40A CIRC BRKRS SUPPLYING
OVEN & STOVE SHOULD BE REPL WITH 30A DUE
TO CONDUCTOR SIZE. INTERIOR PANEL
APPEARS TO BE ORIGINAL WITHOUT NEW OR
ALTERED CONDUCTORS, SUPPLIED WITH 4-WIRE
FEEDER PROTECTED AT 100A BRKR AT
SERVICE; NO BATH RECEPT OUTLET.

UNIT #2: NO INTERIOR ACCESS; UNKNOWN IF
AN INTERIOR PANEL EXISTS.

ELEC SERVICE (EXTERIOR): SVC PANEL
MISSING DEADFRONT, NO LABELING. OBSERVED
60A CIRCUIT WITHOUT NEUTRAL -- IF
SUPPLYING AN INTERIOR PANEL A NEUTRAL
CONDUCTOR IS REQUIRED.

FEEDER PANEL ADJACENT TO SERVICE: NO
DIRECT OVERCURRENT PROTECTION ON
FEEDERS; NO EQUIPMENT GROUNDING
CONDUCTOR; ENCLOSURE IS NEMA 1 (DRY
LOCATION RATED); OPEN BREAKER SPACES IN
DEADFRONT; SUPPLIED CIRCUITS INCLUDE
OPEN CONDUCTORS AND CABLES.

MINI-SPLIT AC UNITS (3): NO
DISCONNECTING MEANS; OPEN CORDS, SOME
PASSING THROUGH EXTERIOR WALL; RECEPT
COVERS DO NOT REMAIN W/P WITH PLUGS
INSERTED; MULTIPLE INSTALLATIONS OF TYPE
UF CABLE LYING ON GROUND OR SECURED TO
EXTERIOR WALLS WITHOUT PROTECTION.
07-16-202508:52 AMUPDATE/NOTES07-16-2025 CEO/YC CALLED RESPONDENT TO
VERIFY APPOINTMENT TO INSPECT PROPERTY
THEY STATED THEY WILL BE WAITING FOR
INSPECTION AS/YC 15 MIN
07-14-202504:27 PMUPDATE/NOTES07-14-2025 SOMEONE CALLED BACK AND
STATED WENSDAY 07-14-2025 AT 11AM CEO
CAN INSPECT THE PROEPRTY CEO HAS UPDATED
EL/CODE STAFF ON THE CASE EL STATED HE
WILL GO WITH CEO TO MAKE INSPECTION AS
15 MIN
07-14-202504:24 PMUPDATE/NOTES07-14-2025 RESPONDENT NELSON OTI CALLED
CEO/YC BACK STATED THEY DID NOT KNOW
ABOUT THE NEW COMPLAINT THEY LIVE IN
MIAMI HE STATED HE WILL HAVE TO GET WITH
THE RENTERS TO SCHEDUAL A TIME/DATE TO
TO INSPECT THE PROPERTY HE STATED HE
WILL CALL BACK WHEN HE HAS THE TIME AND
DATE. AS 15 MIN
07-14-202504:23 PMUPDATE/NOTES07-14-2025 CEO/YC CALLED RESPONDENT
(305-879-3066 AND LEFT VM TO CALL CEO
BACK AS 15 MIN
07-11-202502:26 PMCREATE COMPLAINTCOMPLAINT RECORDED BY BSINGLEY
Copyright © 2008 – THE PLUS SERIES ® – All Rights Reserved