PREMOVE INSPECTION
Inspections/Events Detail
DATETIMEINSPECTION / EVENT TYPEINSTRUCTIONS / COMMENTS
08-30-202404:48 PMREINSPECTION 
08-16-202404:48 PMINITIAL INSPECTIONTHIS IS A DOUBLEWIDE MOBILE HOME OF
UNKNOWN ORIGIN OR MAKE AND MODEL. HOME
HAS HAD EXTENSIVE REMODEL WORK
COMPLETED. I WILL NEED THE OWNER TO
PROVIDE MAKE AND MODEL DOCUMENTATION TO
DETERMINE FULL EXTENT OF REHABILITATION.
THERE ARE ISSUES WITH PLUMBING SYSTEM
AND ELECTRICAL SYSTEM THAT WILL REQUIRE
CORRECTION.
1. THE WATER HEATER RELIEF PIPING IS
MISSING.
2. THE DRAIN PIPING ON THE SINKS WILL
HAVE TO BE REPLACED WITH CODE COMPLIANT
PIPING.
3. GFCI PROTECTED OUTLETS WILL NEED TO
BE VERIFIED IN THE KITCHEN AND BATHROOM
AREAS.
4. AN OPERABLE SMOKE DETECTOR WILL NEED
TO BE VERIFIED.
5. THE INSULATION AND BOTTOM BOARD WILL
NEED TO BE REPAIRED/REPLACED.
6. ALL ELECTRICAL FIXTURES WILL NEED TO
BE IN PLACE WITH PROPER COVERS.
7. THE MOST CONCERNING ISSUE IS THE
ADDITION OF A FIREPLACE TO THIS UNIT. A
LARGE LIVING ROOM WINDOW HAS BEEN
REMOVED AND A FIREPLACE MANTLE HAS BEEN
CONSTRUCTED. THIS AREA WILL NEED TO BE
ALTERED TO PROVIDE PROPER FIRE
SEPERATION BETWEEN THE FIRE PLACE UNIT
AND COMBUSTIBLE CONSTRUCTION.
8. ADDITIONAL CONCERN IS THE FLOORING
AND NEW CABINET TOP CONSTRUCTION. WHILE
VERY NICE LOOKING, THE FLOORING, CABINET
TOPS AND FIREPLACE MANTLE ARE
MARBLE/TILE PRODUCTS. WALL COVERING HAS
ALSO BEEN REPLACED WITH 1/2" DRYWALL
THROUGHOUT HOME. THE ADDITIONAL WEIGHT
OF THESE PRODUCTS WILL NEED TO BE
INVESTIGATED BY AN ENGINEER TO DETERMINE
IF THE FRAME OF THIS UNIT HAS BEEN
OVERLOADED. THIS IS WHY WE WILL NEED
MAKE AND MODEL INFORMATION.
08-14-202411:54 AMCREATE COMPLAINTCOMPLAINT RECORDED BY AMHERNAN