Code Enforcement Detail
Code Enforcement Detail
Case Number CE20030203 complainant  
Case Date 03-31-2020 address  
Origination   -   Status C - CLOSED
Operator nsulliva Officer ERIC
Fines Balance $0.00
Lien Balance $0.00
Total Balance $0.00
Property On Case
STRAP NBR C-22-37-30-600-0110-0010 Owner JARAMILLO JESICA
Unit   Owner Address 140 CUMBERLAND ST
Property Address 145 HIGHLANDS BLVD City/State/Zip LAKE PLACID FL 33852
City/State/Zip LAKE PLACID FL 33852 Phone  
Case Description
PRE-MOVE MOBILE HOME
145 HIGHLANDS BLVD LAKE PLACID
CONTACT:FERNANDO SILVA
PHONE: 727-506-0351
Inspections/Events Detail
DATETIMEINSPECTION / EVENT TYPEINSTRUCTIONS / COMMENTS
05-11-202006:02 PMCLOSE COMPLAINTCLOSE FUNCTION BY ELONGSHO
05-11-202006:00 PMINITIAL INSPECTIONTHIS IS A DOUBLEWIDE MOBILE HOME IN FAIR
CONDITION. STRUCTURALLY SOUND BUT IN
NEED OF COSMETIC REPAIRS. THE FOLLOWING
ITEMS WILL NEED TO BE ADDRESSED BEFORE
CERTIFICATE OF OCCUPANCY IS ISSUED.
1. THE INSULATION AND BOTTOM BOARD NEEDS
TO BE REPAIRED/REPLACED.
2. BOTH SKYLIGHTS HAVE ALLOWED WATER
INTRUSION. ONE HAS BEEN ELIMINATED BUT
REPAIRS TO THE CEILING IN THIS AREA HAVE
NOT BEEN MADE. BOTH SKYLIGHTS NEED TO BE
REPLACED OR ELIMINATED AND DAMAGE
REPAIRED.
3. THERE ARE MULTIPLE AREAS WHERE THE
WALLS HAVE EITHER BEEN REMOVED OR HAVE
HOLES. ALL CEILINGS AND WALLS MUST BE
REPAIRED TO NOT HAVE HOLES OR DAMAGE.
4. THERE ARE TWO INTERIOR DOORS THAT
HAVE DAMAGE. INTERIOR DOORS MUST NOT
HAVE HOLES OR DAMAGE AND MUST FIT THE
OPENING AND HAVE PROPER HARDWARE.
5. THE HALL BATHROOM DOES NOT HAVE A
DOOR INSTALLED. BATHROOMS MUST HAVE A
DOOR WITH HARDWARE TO PROVIDE PRIVACY.
6. THE HALL BATH SINK DRAIN PIPING HAS
BEEN REMOVED. A NEW TRAP AND DRAIN
PIPING MUST BE INSTALLED USING LISTED
MATERIALS.
7. THE KITCHEN SINK CABINET HAS SEVERE
DAMAGE. THE BOTTOM OF THIS CABINET MUST
BE REPAIRED/REPLACED TO NOT HAVE HOLES.
8. MULTIPLE ELECTRICAL DEVICES DO NOT
HAVE COVERS AND THERE ARE LIGHTING
FIXTURES MISSING. ALL ELECTRICAL DEVICES
AND FIXTURES MUST BE PROPERLY INSTALLED.
9. THE A/C SYSTEM HAS BEEN REMOVED. IF
UNIT IS NOT REPLACED THE SUPPLY DUCT
WILL NEED A DROPOUT INSTALLED. IF SYSTEM
IS REPLACED THE A/C DUCTWORK MUST BE
R-8.
10. GFCI PROTECTED OUTLETS MUST BE
INSTALLED IN THE KITCHEN AND BATHROOM
AREAS.
11. AN OPERABLE SMOKE DETECTOR WILL HAVE
TO BE INSTALLED.
03-31-202003:53 PMCREATE COMPLAINTCOMPLAINT RECORDED BY NSULLIVA