-     My Account  
   

Log in is not required to search. In the red banner above select: I Want To > Search > Permits

Code Enforcement Detail
Code Enforcement Detail
Case Number CE20030056 complainant  
Case Date 03-11-2020 address  
Origination   -   Status A - ACTIVE (VERIFIED)
Operator mcarner Officer ERIC
Fines Balance $0.00
Lien Balance $0.00
Total Balance $0.00
Property On Case
STRAP NBR C-24-35-28-110-0110-0120 Owner THE RIGHT FUND I LLC
Unit   Owner Address 13795 NE 20TH PL
Property Address 582 RUTHERFORD BLVD City/State/Zip MIAMI FL 33181
City/State/Zip SEBRING FL 33875- Phone  
Case Description
PRE-MOVE INSPECTION @
582 RUTHERFORD BLVD SEBRING
JOSE GARDUNO
#239-633-3028
Inspections/Events Detail
DATETIMEINSPECTION / EVENT TYPEINSTRUCTIONS / COMMENTS
03-13-202004:51 PMINITIAL INSPECTIONTHIS IS A DOUBLEWIDE UNIT IN GOOD
STRUCTURAL CONDITION BUT NEEDS SOME
REPAIRS. THE FLOOR INSULATION AND BOTTOM
BOARD WILL NEED TO BE REPAIRED/RPLACED.
ALL OF THE WINDOWS WILL NEED TO BE MADE
OPERABLE.
GFCI PROTECTED OUTLETS WILL NEED TO BE
INSTALLED IN THE BATHROOMS AND KITCHEN
AREAS.
AN OPERABLE SMOKE DETECTOR WILL NEED TO
BE INSTALLED.
THE ELECTRICAL SYSTEM BENEATH THE UNITS
HAVE SEVERAL CONNECTIONS THAT ARE NOT IN
APPROVED BOXES.
THERE IS A CEILING FAN IN ONE OF THE
ROOMS THAT HAS DRAPED WIRING THAT WILL
HAVE TO BE IN APPROVED COVER.
THERE ARE A COUPLE OF HOLES IN THE
INTERIOR WALLS THAT WILL NEED TO BE
REPAIRED.
UNIT IS APPROVED FOR WIND ZONE 2.
A/C DUCTWORK WILL HAVE TO BE R-8.

03-11-202011:48 AMCREATE COMPLAINTCOMPLAINT RECORDED BY MCARNER
Copyright © 2008 – THE PLUS SERIES ® – All Rights Reserved