-     My Account  
   

Log in is not required to search. In the red banner above select: I Want To > Search > Permits

Code Enforcement Detail
Code Enforcement Detail
Case Number CE18040160 complainant  
Case Date 04-30-2018 address  
Origination PHONE - TELEPHONE CALL RECEIVED Status C - CLOSED
Operator hlopez Officer ERIC
Fines Balance $0.00
Lien Balance $0.00
Total Balance $0.00
Property On Case
STRAP NBR A-22-33-28-010-0700-0010 Owner CITY OF AVON PARK
Unit   Owner Address 110 E MAIN ST
Property Address 101 W MAIN ST City/State/Zip AVON PARK FL 33825
City/State/Zip AVON PARK FL 33825 Phone  
Case Description
REQUEST INSPECTION
Inspections/Events Detail
DATETIMEINSPECTION / EVENT TYPEINSTRUCTIONS / COMMENTS
09-05-202504:04 PMCLOSE COMPLAINTCASE CLOSED BY ELONGSHO
01-05-202104:04 PMREINSPECTIONPERMIT #20100821 HAS BEEN ISSUED FOR
DEMOLITION OF THIS STRUCTURE. CLOSE
CASE.
05-07-201805:55 PMINITIAL INSPECTIONMADE SITE VISIT WITH JASON LISTER TO
INSPECT THIS PROPERTY. PROPERTY IS OWNED
BY THE CITY. THIS STRUCTURE IS A TWO
STORY BUILDING IN THE DOWNTOWN AREA.
BUILDING HAS BEEN ABANDONED AND HAS
BROKEN AND BOARDED WINDOWS. INTERIOR
INSPECTION SHOWS TERMITE INFESTATION
RESULTING IN MASSIVE DECAY. WOOD FLOOR
SYSTEM OF THE SECOND FLOOR SHOWS
EVIDENCE OF FAILURE. THE SECOND FLOOR
HAS BEEN GUTTED TO THE STUD WALL
FRAMING. BROKEN WINDOWS HAVE ALLOWED
BIRDS TO ENTER AND ROOST WITHIN THE
STRUCTURE. WEEDS HAVE GROWN UP THE SOUTH
EXTERIOR WALL TO SECOND FLOOR WINDOW
HEIGHT AND ARE GROWING WITHIN THE
STRUCTURE. THE ROOF SYSTEM IS SUSPECT TO
STRUCTURAL STABILITY. THE NORTH EXTERIOR
WALL HAS BOWED OUTWARD AT MID POINT.
THIS WALL IS OUT OF PLUMB BY 1 1/4"- 1
1/2" IN FOUR FEET. THIS BOWING HAS
CAUSED THE TILE TRIM WORK ON THE
EXTERIOR OF THE BUILDING TO LOOSEN AND
FALL OFF OF THE WALL. OTHER REMAINING
TILE WORK SHOWS CRACKS AND LOOSENING AND
IS IN DANGER FALLING OFF ALSO.
STRUCTURAL STABILITY OF THIS ENTIRE
STRUCTURE IS IN QUESTION. COSTS OF
REPAIR WILL CERTAINLY EXCEED APPRAISED
VALUE IF ATTAINABLE AT ALL. I WOULD
RECOMMEND DEMOLITION AND REMOVAL FROM
THE SITE. THIS DEMOLITION WILL REQUIRE
PROFESSIONAL CARE AS THIS STRUCTURE
SHARES A COMMON WALL WITH THE STRUCTURE
TO THE WEST. THIS WALL WILL NEED TO BE
FINISHED ON THE EXTERIOR TO LEAVE
EXISTING BUILDING ENVELOPE WEATHER
RESISTANT TO ELEMENTS.
04-30-201809:01 AMCREATE COMPLAINTCOMPLAINT RECORDED BY HLOPEZ
Copyright © 2008 – THE PLUS SERIES ® – All Rights Reserved