Code Enforcement Detail
Code Enforcement Detail
Case Number CE16120277 complainant  
Case Date 12-30-2016 address  
Origination   -   Status C - CLOSED
Operator nsulliva Officer ERIC
Fines Balance $0.00
Lien Balance $0.00
Total Balance $0.00
Property On Case
STRAP NBR C-14-37-29-050-0450-0010 Owner BENNETT E D + EDITH J-LAINE
Unit   Owner Address 131 MCKINLEY AVE
Property Address 131 MCKINLEY AVE City/State/Zip LAKE PLACID FL 33852
City/State/Zip LAKE PLACID FL 33852 Phone  
Case Description
NEW AIR CONDITIONING SYSTEM INSTALLED BY
ABSOLUTELY COOL INC NOT PRPPERLY INSTALLED
THEREFORE SYSTEM NOT PROPERLY WORKING, MOLD AND
MILDEW . NO PERMIT
Inspections/Events Detail
DATETIMEINSPECTION / EVENT TYPEINSTRUCTIONS / COMMENTS
05-01-201707:02 PMCLOSE COMPLAINTCASE CLOSED BY ELONGSHO
05-01-201707:02 PMREINSPECTIONHAD MEETING WITH CONTRACTOR WHO ZAID HE
WOULD CORRECT IZZUEZ WITH INZTALLATION.
LATER CONFIRMED WITH OWNER THAT
CORRECTIONZ HAVE BEEN MADE CLOZE CAZE.
01-06-201705:08 PMINITIAL INSPECTIONARRANGED MEETING WITH OWNER TO INSPECT
A/C INSTALLATION AND DISCUSS CONCERNS
WITH JOB. THERE ARE SOME ISSUES WITH THE
INSTALLATION, THE CEILING IS NOT SEALED
AROUND THE RETURN DUCT ALLOWING THE
INSULATION FROM THE ATTIC TO FALL INTO
THE HOME AND THE COMPRESSOR UNIT IS NOT
ANCHORED DOWN. THE CUSTOMER ALSO HAS
CONCERN THAT THE UNIT IS NOT FUNCTIONING
PROPERLY. WHILE I WAS THERE THE UNIT WAS
SET ON 72 DEGREES AND THE OUTSIDE
TEMERATURE WAS 74 DEGREES. I WAS THERE
FOR 30-45 MINUTES DOING INSPECTION AND
THE UNIT RAN CONTINUOSLY NEVER SHUTTING
DOWN. A POSSIBLE FLAW MAY BE THAT THE
SUPPLY PLENUM IS DOWNSIZED DUE TO A
TRUSS MEMBER OVER THE UNIT PLACEMENT.
THE CUSTOMER ALSO SHARED THAT WHILE
ADDING INSULATION TO THE ATTIC IT WAS
DISCOVERED THAT A SUPPLY DUCT WAS
DAMAGED AND DISCONNECTED. REPAIRS WERE
MADE BY OWNER. THERE IS ALSO MOLD AROUND
SOME OF THE DIFFUSERS. OWNER SAYS THAT
HE CLEANS THEM BUT THE MOLD RETURNS. THE
CEILING WILL HAVE TO BE SEALED AROUND
THE RETURN DUCT. THE COMPRESSOR WILL
HAVE TO BE ANCHORED DOWN. THE UNIT WILL
HAVE TO BE CHECKED FOR PROPER FUNCTION
AND AIR FLOW. THE CAUSE OF THE MOLD AT
THE DIFFUSERS WILL HAVE TO BE
INVESTIGATED AND REMEDIED AND ALL OF THE
DUCTWORK WILL HAVE TO BE CHECKED AND
CERTIFIED TO MEET CURRENT CODE
REQUIREMENTS.
12-30-201604:39 PMCREATE COMPLAINTCOMPLAINT RECORDED BY NSULLIVA