Code Enforcement Detail
Code Enforcement Detail
Case Number CE16120002 complainant  
Case Date 12-01-2016 address  
Origination PHONE - TELEPHONE CALL RECEIVED Status C - CLOSED
Operator cshackel Officer ERIC
Fines Balance $0.00
Lien Balance $0.00
Total Balance $0.00
Property On Case
STRAP NBR C-05-35-29-120-0000-0010 Owner UNITED ELITE INVESTMENTS INC
Unit 0006 Owner Address 104 STEPHENSON TER
Property Address 1801 KENT DR City/State/Zip NEW YORK NY 10510
City/State/Zip SEBRING FL 33870- Phone  
Case Description
TENANT COMPLAINT. LANDLORD IS MIKE NAGEL, WITH
PEACELAND PROPERTIES.
FIRE DEPARTMENT TOLD THEM THAT IS NOT SAFE TO LIVE
THERE. CENTRAL AIR DRIPS ON WIRING AND CAUSES
SPARKS. FIRE DEPT TOLD THEM TO CALL BLDG DEPT.
PLACE IS UNSAFE. BLACK MOLD ON WALLS ETC. FROM
LEAKING A/C. NO SCREENS IN THE WINDOWS, YOU HAVE
TO PUT SOMETHING IN THE WINDOWS TO PROP THEM OPEN.
OTHER AREAS OF ELECTRICALLY PROBLEMS, NO LIGHTING
IN MASTER BEDROOM, ETC. NO LIGHTING IN THE KITCHEN
ETC.
SUSAN RUIZ, 863-594-8822.
Inspections/Events Detail
DATETIMEINSPECTION / EVENT TYPEINSTRUCTIONS / COMMENTS
05-15-201705:21 PMCLOSE COMPLAINTCASE CLOSED BY ELONGSHO
05-15-201705:21 PMREINSPECTIONNO FURTHER COMPLAINTS AT THIS ADDRESS.
ASSUME REPAIRED. CLOSE CASE.
12-01-201610:47 PMINITIAL INSPECTIONMADE SITE VISIT AND SPOKE WITH TENANT.
MAINTENANCE MAN/ ELECTRICIAN WAS THERE
AND HAD INVESTIGATED THE ELECTRIC
ISSUES. THE A/C AIR HANDLER CONDENSATION
WAS DRIPPING ON TOP OF THE WATER HEATER
AND WATER HAD COLLECTED IN WIRE BOX TO
CAUSE SHORT CIRCUITING. WIRING HAD BEEN
REPAIRED BUT A/C UNIT NEEDS TO BE
SERVICED AS UNIT HAS BEEN RUN WITHOUT
FILTER CAUSING THE COILS TO COLLECT DIRT
CAUSING EXCESSIVE MOISTURE/
CONDENSATION. WINDOWS DO NOT HAVE
OPERATORS TO HOLD IN OPEN POSITION. THIS
IS A VIOLATION OF STANDARD HOUSING CODE
SECTION 12.19.305. TENANT ALSO POINTED
OUT THAT KITCHEN LIGHT DID NOT WORK.
INVESTIGATION SHOWED THAT WIRING WAS
ENERGIZED CORRECTLY AND THAT WIRING AT
FIXTURE WAS NOT CONNECTED. TENANT ALSO
SHARED THAT ELECTRICAL LIGHT SWITCH IN
MASTER BEDROOM CONTROLED THE BRANCH
CURCUIT TO THE 2ND BEDROOM.
INVESTIGATION REVEALED THAT MASTER
BEDROOM OUTLET THAT SWITCH CONTROLED WAS
WIRED WRONG CAUSING THIS ISSUE. NEITHER
OF THESE ELECTRICAL ISSUES ARE SAFETY
CONCERNS. THE TILE BACK SPLASH IN THE
TUB/SHOWER IS DAMAGED AROUND THE VALVE
LEAVING A HOLE AROUND THE VALVE ALLOWING
WATER INTRUSION INTO WALL CAVITY. THIS
NEEDS TO BE REPAIRED AS OVER TIME THIS
WILL CAUSE STRUCTURAL DAMAGE TO WALL
FRAMING.
12-01-201609:38 AMCREATE COMPLAINTCOMPLAINT RECORDED BY CSHACKEL