Code Enforcement Detail
Code Enforcement Detail
Case Number CE16030063 complainant  
Case Date 03-09-2016 address  
Origination SREQ - FROM SR SYSTEM Status C - CLOSED
Operator nsulliva Officer ERIC
Fines Balance $0.00
Lien Balance $0.00
Total Balance $0.00
Property On Case
STRAP NBR C-22-37-30-600-0260-0080 Owner PEACELAND ESTATES INC
Unit   Owner Address 14825 NE 9TH AV
Property Address 134 ORANGE ST City/State/Zip MIAMI FL 33161
City/State/Zip LAKE PLACID FL 33852 Phone  
Case Description
MIKE (PEACELAND ESTATES INC) CAME INTO THE
BUILDING DEPT TO PURCHSE AN ELECTRICAL RECONNECT
PERMIT FOR THE ABOVE ADDRESS. PROPERTY APPRAISER
SHOW THIS LAND AS VACANT W/ OLD UNLIVEABLE MOBILE
HOME AND REMOVED FROM THE GARBAGE TAX ROLL YEAR
2012 PER BEA JOHNSON (NAV) PLEASE INSPECT FOR
STATUS UPDATE.
CONTACT PERSON: MIKE @ 863-243-9191.
Inspections/Events Detail
DATETIMEINSPECTION / EVENT TYPEINSTRUCTIONS / COMMENTS
01-04-201709:34 AMCLOSE COMPLAINTCASE CLOSED BY ELONGSHO
01-04-201709:34 AMREINSPECTIONPERMIT #16030538 HAS BEEN OBTAINED FOR
REHABILITATION OF THIS PROPERTY. FINAL
INSPECTION WAS MADE ON 12/30/16. SEPTIC
SYSTEM HAS BEEN CERTIFIED AND STRUCTURE
HAS BEEN ISSUED A CERTIFICATE OF
OCCUPANCY. CLOSE CASE.
05-23-201607:25 PMREINSPECTIONRECEIVED CALL FROM MIKE AT PEACELAND
PROPERTIES REQUESTING INSPECTION OF WORK
PERFORMED. THE WALL SECTION IN THE
LIVING ROOM HAS BEEN REPAIRED AND MOST
OF THE FLOOR, JUST A COUPLE OF AREAS
THAT ARE STILL WEAK. MET KEYON ONSITE
AND DID WALK THRU WITH HIM. THE BLOCK
AND TIE SYSTEM STILL NEEDS TO BE
CERTIFIED BY AN INSTALLER. THE SEPTIC
SYSTEM NEEDS TO BE CERTIFIED. SCREENS
HAVE BEEN INSTALLED ON THE WINDOWS AND
THEY ARE OPERABLE BUT LOCKS NEED TO BE
INSTALLED ON SOME OF THE WINDOWS. THE
PLUMBING NEEDS TO BE CONNECTED TO THE
HALL BATH SINK AND THE PLUMBING PIPES
NEED TO BE SECURED IN THE LAUNDRY AREA.
SOME LIGHT FIXTURES STILL NEED TO BE
INSTALLED ALONG WITH SMOKE DETECTOR AND
GFCI OUTLETS. PERMIT HAS BEEN ISSUED FOR
THIS WORK.
03-10-201605:38 PMINITIAL INSPECTIONTHIS IS A DOUBLEWIDE MOBILE HOME THAT
HAS BEEN REMOVED FROM THE TAX ROLLS AS
UNINHABITABLE. PEACELAND PROPERTIES
REQUESTED AN INSPECTION TO DETERMINE
REPAIRS NEEDED TO MEET BUILDING AND
STANDARD HOUSING CODES. THERE HAS BEEN
EXTENSIVE REPAIRS PERFORMED ON THIS
PROPERTY AT THIS TIME BUT MUCH MORE
NEEDED TO MEET CODE REQUIREMENTS. THE
BLOCK AND TIE SYSTEM OF THE MOBILE UNITS
WILL HAVE TO BE BROUGHT UP TO CURRENT
CODE REQUIREMENTS. THIS WILL HAVE TO BE
ACCOMPLISHED BY A CERTIFIED MOBILE HOME
INSTALLER AND A PERMIT WILL BE REQUIRED.
THE INSULATION AND BOTTOM BOARD BENEATH
MOBILE HOME WILL HAVE TO BE
REPAIRED/INSTALLED PER CURRENT CODE
REQUIREMENT. THE SEPTIC SYSTEM WILL HAVE
TO BE CERTIFIED BY A SEPTIC SYSTEM
INSTALLER AND APPROVED BY THE HEALTH
DEPARTMENT. ALL OF THE WINDOWS WILL HAVE
TO BE MADE OPERABLE OR REPLACED. SASHES
MUST REMAIN IN OPEN POSITION WHEN OPENED
AND SCREENS MUST BE INSTALLED. THE SOUTH
EXTERIOR WALL IN THE LIVING ROOM AND
FRONT BEDROOM IS NOT SECURED TO THE
TRAILER FRAME AT THE BOTTOM. THIS WILL
HAVE TO BE INVESTIGATED AND REPAIRED
WITH PROPER ANCHORING. GFCI PROTECTED
OUTLETS WILL HAVE TO BE INSTALLED IN THE
KITCHEN AND BATHROOM AREAS. AN OPERABLE
SMOKE DETECTOR WILL HAVE TO BE
INSTALLED. THE PLUMBING PIPES IN THE
UTILITY AREA WILL HAVE TO BE SECURED TO
FRAMING MEMBERS. THE PLUMBING IN THE
HALL BATHROOM WILL HAVE TO BE COMPLETED.
THE WATER SUPPLY IS NOT CONNECTED TO THE
TOILET NOR THE SINK AND THE DRAIN PIPING
IS NOT CONNECTED TO THE SINK. THE ENTIRE
PLUMBING SYSTEM WILL NEED TO BE
INSPECTED FOR COMPLIANCE. THE ELECTRICAL
SYSTEM APPEARS TO BE IN RELATIVELY GOOD
CONDITION BUT THERE ARE SOME LIGHT
FIXTURES THAT WILL NEED TO BE INSTALLED
AND ELECTRIC OUTLETS THAT NEED TO BE
SECURED IN PLACE. THERE ARE SEVERAL WEAK
SECTIONS IN THE FLOOR, THE MASTER BATH,
MASTER CLOSET, MASTER BEDROOM, FRONT
BEDROOM TO MENTION A FEW. ALL OF THE
FLOOR SYSTEM WILL HAVE TO BE
STRUCTURALLY SOUND AND INTACT NOT
ALLOWING EXPOSURE TO EXTERIOR
ENVIRONMENT. TWO SEPERATE PERMITS WILL
BE REQUIRED FOR THIS PROJECT, ONE FOR
THE BLOCK AND TIE SYSTEM AND ANOTHER FOR
THE INTERIOR REPAIRS/ WINDOW
REPLACEMENT.
03-09-201604:30 PMCREATE COMPLAINTCOMPLAINT RECORDED BY NSULLIVA