Case Description
PREMOVE MOBILE HOME INSPECTION
(ADDRESS: 303 FRANCIS ST)
Inspections/Events Detail
DATETIMEINSPECTION / EVENT TYPEINSTRUCTIONS / COMMENTS
02-23-201606:07 PMINITIAL INSPECTIONTHIS IS AN OLDER MODEL SINGLE WIDE
MOBILE HOME IN GOOD CONDITION. THE SMOKE
DETERCTOR NEEDS TO BE REPLACED OR MADE
OPERABLE. GFCI PROTECTED OUTLETS NEED TO
BE INSTALLED IN THE KITCHEN AND BATHROOM
AREAS. THE EXPOSED ELECTRICAL WIRING AT
THE PANEL NEEDS TO BE CONCEALED AND THE
ABANDONED WIRING AT THE OLD WATER HEATER
LOCATION NEEDS TO BE REMOVED. THE WATER
HEATER SUPPLY PIPING NEEDS TO BE 3/4"
AND THE RELIEF DISCHARGE PIPING ALSO
NEEDS TO BE 3/4". THE HVAC DUCTWORK WILL
HAVE TO BE R8 TO MEET NEW CODE
REQUIREMENT. THERE IS NO DATA PLATE
INFORMATION ON UNIT BUT VISUAL
INSPECTION WOULD DETERMINE CLIMATE ZONE
AND WIND ZONE REQUIREMENTS MET. THE
ATTACHED SCREENROOM AND CARPORT WILL
HAVE TO BE BROUGHT UP TO CURRENT CODE
REQUIREMENTS IF THEY ARE TO BE
REINSTALLED.
02-22-201608:39 AMCREATE COMPLAINTCOMPLAINT RECORDED BY NSULLIVA
Copyright © 2008 – THE PLUS SERIES ® – All Rights Reserved