-     My Account  
   

Log in is not required to search. In the red banner above select: I Want To > Search > Permits

Code Enforcement Detail
Code Enforcement Detail
Case Number CE16020094 complainant  
Case Date 02-10-2016 address  
Origination PHONE - TELEPHONE CALL RECEIVED Status C - CLOSED
Operator jmccoy Officer CENTRAL
Fines Balance $0.00
Lien Balance $0.00
Total Balance $0.00
Property On Case
STRAP NBR C-29-35-30-A00-0121-0000 Owner BAILLIE INVESTMENTS INC
Unit   Owner Address 8015 ELLIOTT RD LOT 14
Property Address 8015 ELLIOTT RD City/State/Zip SEBRING FL 33876
City/State/Zip SEBRING FL 33870 Phone  
Case Description
2/10/16 PHONE COMPLAINT RE: BURNED DOWN MOBILE
HOME LOT 11 OR 12. AROUND SECOND CURVE FIRST HOUSE
ON RIGHT. JAM
Inspections/Events Detail
DATETIMEINSPECTION / EVENT TYPEINSTRUCTIONS / COMMENTS
03-30-201611:14 AMCLOSE COMPLAINTCASE CLOSED BY AHARTSEI
03-28-201611:14 AMINITIAL INSPECTION03-28-16 THIS IS LOT 15 / RECIEVED THIS
CASE FROM ERIC AND COMPLETED AN
INSPECTION/ THE OWNER HAS OBTAINED THE
PERMIT AND THE LADY WAS AT THE HOME AT
THE TIME OF MY INSPECTION AND SHE WAS
SCRUBBING THE SOOT OFF OF THE INSIDE OF
THE PATIO ROOF / NO NEED FOR ANY
INSPECTIONS FROM CE SINCE THE BLD DEPT
WILL INSPECT ON THE PERMIT /AH
03-14-201601:31 PMREINSPECTION 
03-10-201601:31 PMREINSPECTIONRECEIVED CALL THAT REPAIRS WERE BEING
MADE WITHOUT PERMITTING. WENT TO SITE
AND SPOKE WITH OWNER. REPAIRS ARE IN
PROGRESS BUT NOT TO POINT THAT
INSPECTION CAN NOT BE DONE. TOLD OWNER
TO OBTAIN PERMIT AND INSPECTION WOULD
NEED TO BE DONE BEFORE FURTHER WORK
PERFORMED. HE WAS VERY COMPLIANT AND
SAID HE WOULD BE IN ON MONDAY TO OBTAIN
PERMIT.
02-15-201604:46 PMINITIAL INSPECTIONTHIS IS A SINGLE WIDE MOBILE HOME THAT
HAS SUFFERED FIRE DAMAGE. DAMAGE IS
MOSTLY DUE TO SMOKE AND FIRE FIGHTING
ACTIVITY. MINOR STRUCTURAL DAMAGE WAS
EVIDENT TO TWO 2X4 STUDS BETWEEN WINDOWS
AT FIRE INITIATION POINT ON THE WEST
SIDE. THESE STUDS WERE BURNED AND
COMPROMISED APPROXIMATELY HALF WAY UP
THE WALL. THE STUDS WERE STILL SECURED
AT THE TOP PLATE AND THE BOTTOM PLATE
AREAS. THEY WILL NEED TO BE REPLACED.
THE CEILING WAS TORN DOWN BY FIRE
FIGHTERS EXPOSING THE TRUSS SYSTEM WHICH
SHOWED NO SIGNS OF FIRE DAMAGE. THE
SIDING ON THE EXTERIOR OF THE STRUCTURE
HAD ALSO BEEN PULLED LOOSE EXPOSING THE
BOTTOM FRAME LEDGER AND THE STUDS IN THE
WALL. THE BOTTOM LEDGER WAS CHAREDAND
SHOWED SIGNS OF FIRE BUT WAS INTACT AND
STRUCTURALLY SOUND WITH STRAPPING STILL
INTACT AND SECURE TO THE STUDS IN THE
WALL. INSULATION IN THE CEILING AND
WALLS HAD NOT IGNITED ALTHOUGH SOME OF
THE PAPER FACING HAD BURNT. THE HOME HAS
EXTENSIVE SMOKE DAMAGE THAT WILL HAVE TO
BE TREATED AND THE TWO WINDOWS AT THE
SOURSE OF THE FIRE ARE BROKEN AND WILL
HAVE TO BE REPLACED. THE SIDING WILL
HAVE TO BE REPAIRED FROM FIRE FIGHTING
ACTIVITY. WITH THE WINDOWS UNSECURE THE
STRUCTURE NEEDS TO HAVE PLYWOOD
INSTALLED TO COVER AND SECURE THE
STRUCTURE FROM ENTRY AND POSSIBLE
INJURY.
02-10-201604:21 PMCREATE COMPLAINTCOMPLAINT RECORDED BY JMCCOY
Copyright © 2008 – THE PLUS SERIES ® – All Rights Reserved