Case Number CE13100126 complainant  
Case Date 10-18-2013 address  
Origination CEOFF - CODE ENFORCEMENT OFFICER Status O - OPEN (UNVERIFIED)
Operator hmckinne Officer SY
Fines Balance $0.00
Lien Balance $0.00
Total Balance $0.00
Property On Case
STRAP NBR A-15-33-28-050-00D0-0070 Owner SELPH JAMES R JR + PATRICIA D
Unit   Owner Address 1124 N LAKE REEDY BLVD
Property Address 104 E THOMAS ST City/State/Zip FROSTPROOF FL 33843
City/State/Zip AVON PARK FL 33825 Phone  
Case Description
AVON PARK CODE ENFORCEMENT REQUESTS INSPECTION OF
THIS SITE.
Inspections/Events Detail
DATETIMEINSPECTION / EVENT TYPEINSTRUCTIONS / COMMENTS
03-11-201401:32 PMINITIAL INSPECTIONVIOLATES 12.19.500. SYM INSPECTED
03/11/2014
I MET WITH THE OWNER TO DO AN INTERIOR
INSPECTION OF THE HOME. I FOUND SEVERAL
AREAS OF TERMITE DAMAGE TO THE WALLS.
THERE ARE SEVERAL WEAK SPOTS IN THE
FLOOR WHERE THE FLOOR JOIST HAVE ROTTED
OOFF THE SUPPORT BEAM. THERE ARE AT
LEAST SIX HOLES IN THE FLOOR WHERE
SOMEONE FELL THROUGH THE FLOORING. THE
FRAMING AROUND THE WINDOWS ARE BADLY
EATEN BY TERMITES AND HAVE NO SUPPORTIVE
VALUE. THE TUB IN THE BATHROOM IS
LILING THROUGH THE FLOOR DUE TO ROTTEN
WOOD AND JOIST. DUE TO THE EXTENT OF
DAMAGE AND THE UNSAFE CONDITION OF THE
FLOOR AND WAALS, I RECOMMEND REMOVAL
FROM THE PROPERTY.
10-21-201302:56 PMCREATE COMPLAINTVIOLATES 12.19.304 AND 12.19.305 "E":
THIS IS A WOOD FRAME BUILDING WITH A
RAISED WOOD FLOOR SYSTEM. THE HOME WAS
LOCKED SO NO INTERIOR INSPECTION WAS
MADE. BY OBSERVING THROUGH THE WINDOWS,
I SAW NO SIGNS OF ROOF LEAKS. THERE WAS
A LAYER OF PLYWOOD INSTALLED OVER THE
OLD 1X3 FLOORING. THE FRONT AND REAR
DOORS WERE IN PLACE AND IN GOOD
CONDITION. THE WINDOWS WERE ALL INTACT
ALSO AND APPEARED TO BE IN WORKING
CONDITION. THE WINDOWS WERE ALL INTACT
ALSO AND APPEARED TO BE IN WORKING
CONDITION. THE ROOF IS A 3 TAB SHINGLE
THAT WILL PROBABLY LAST ANOTHER 3 TO 4
YEARS. THE FRONT PORCH FLOORING WAS
WEAK IN SEVERAL PLACES AND HAS SEVERAL
BOARDS NAILED ON TOP OF IT. THESE
BOARDS NEED TO BE REMOVED AND THE PORCH
REDECKED AND HAVE SOME POSSIBLE FLOOR
JOISTS REPLACED ALSO. WITH THIS PROBLEM
FIXED THE HOME SHOULD BE IN LIVABLE
CONDITION SUBJECT TO AN INTERIOR
INSPECTION.