Code Enforcement Detail
Code Enforcement Detail
Case Number CE10030114 complainant  
Case Date 03-19-2010 address  
Origination FIELD - FIELD INSPECTOR Status C - CLOSED
Operator gallen Officer CENTRAL
Fines Balance $0.00
Lien Balance $0.00
Total Balance $0.00
Property On Case
STRAP NBR C-04-35-31-010-0010-0080 Owner AMES BRITTANY JEAN
Unit   Owner Address 1628 HICKS RD
Property Address 1628 HICKS RD City/State/Zip LORIDA FL 33857
City/State/Zip LORIDA FL 33857 Phone  
Case Description
3/19/10 BURNED METAL STORAGE BUILDING. NEED
INSPECTION TO DETERMINE IF STRUCTURE IS SAFE IN
CURRENT CONDITION. REF; TO SY. MOSLEY FOR STANDARD
HOUSING INSPECTION. PHOTOS/30-MN GA
Inspections/Events Detail
DATETIMEINSPECTION / EVENT TYPEINSTRUCTIONS / COMMENTS
09-24-201410:58 AMUPDATE/NOTES9/24--FILE SENT TO RETENTION AND ADDED
TO SPREADHSEET. TED
09-22-201108:33 AMCLOSE COMPLAINTCASE CLOSED BY BSINGLEY
09-22-201108:33 AMREINSPECTION09-22-11 COMPLIED PER SY'S INSPECTION
/AH & BEV
04-08-201102:55 PMSTANDARD HOUSING CODESYM WENT TO SITE 4/08/2011
THE BUILDING WAS PAINTED SOON AFTER THE
FIRE DAMAGE IN MARCH 2010. BOTH ENDS
OF
THE BUILDING HAVE BEEN REPLACED WITH
NEW
METAL. THIS WORKED WELL, BUT THE
PAINTING WILL NEED TO BE REPEATED EVERY
14-18 MONTHS OR IT WILL RUST. THE
LOWER
SIDES ARE STILL OK BUT THE TOP THIRD ON
EACH SIDE NEEDS TO BE CECOATED SOON.
04-04-201110:11 AMUPDATE/NOTES04-04-11 AT 10:18 AM SENT E-MAIL TO SY
TO REINPECT THE PROPERTY FOR COMPLIANCE
ON THE METAL STORAGE BUILDING/AH
03-30-201102:25 PMREINSPECTION3-30-11 OWNER BRITTANY AMES HAS MADE
REPAIRS TO SHED. NEED SY TO DO ANOTHER
INSPECTION TO SEE IF COMPLAINCE. BSS/AH
05-18-201003:47 PMOFFICIAL FORMAFFIDAVITOFP PRINTED BY GALLEN
05-18-201010:08 AMOFFICIAL FORMAFFIDAVITOFP PRINTED BY GALLEN
05-18-201010:05 AMREINSPECTION5/18/10 ISSUED W.CIT5754 FOR 12.19.305
INTERIOR/EXTERIOR BUILDING REQUIREMENTS
PER STANDARD HOUSING REPORT FOR STORAGE
BUILDING. GAVE JOHN AMES(FATHER) COPY OF
REPORT AND W.CITATION. GAVE UNTIL
6/17/10 TO COMPLY WITH NEEDED REPAIRS.
60-MN/PHOTOS GA
04-28-201012:24 PMINITIAL INSPECTIONVIOLATES 12.19.305
THIS IS A METAL FRAME METAL CLAD
ACCESSORY BUILDING. IT IS DAMAGED BY
FIRE IN THE INTERIOR OF THE BUILDING.
THE HEAT FROM THE FIRE HAS CAUSED THE
METAL PANELS TO BUCKLE AND SEPERATE
ATHE
LAP JOINTS. THE FIRE ALSO RUINED THE
GALVANIZED FINISH ON THE WALLS AND THE
ROOF PANELS. THERE NEEDS TO BE REPAIRS
MADE SOON TO PREVENT THE SIDING FROM
RUSTING OUT AROUND THE SCREWS THAT ARE
HOLDING THE PANELS IN PLACE. THE
EXTERIOR SIDING NEEDS TO BE REPLACED IN
MOST AREAS OR PAINTED TO PREVENT THE
RUSTING PROCESS FROM DAMAGING THE
BUILDING. IF THIS IS NOT DONE SOON,
BUILDING WILL NEED TO BE REMOVED FROM
SITE.
03-19-201002:20 PMCREATE COMPLAINTCOMPLAINT RECORDED BY GALLEN