Case Description
UNSAFE STRUCTURE, MOBILE HOME WITH ADDITIONS. JOE
Violation Code(s)
1: 5.6-2(4) -- UNSAFE BUILDING/STRUCTURE
2: INT -- INTEREST ON LIEN
3: SM FINE/LIEN -- SPEC MAGISTRATE DAILY FINE
Inspections/Events Detail
DATETIMEINSPECTION / EVENT TYPEINSTRUCTIONS / COMMENTS
04-09-201303:32 PMUPDATE/NOTES4/9--FILE WENT TO RETENTION AND WAS
ADDED TO THE RETENTION SPREADSHEET. TED
03-11-201011:39 AMCOURT APPEARANCE 
02-08-201012:27 PMCLOSE COMPLAINTCASE CLOSED BY AHARTSEI
02-08-201012:27 PMCHECK FOR COMPLIANCE02-08-10 PROPERTY IN COMPLIANCE / HOME
AND GARAGE REMOVED BY HATHAWAYS WHICH
WAS HIRED BY THE OWNER /AH
02-08-201012:26 PMOFFICIAL FORMA.O.C.-APRIL PRINTED BY AHARTSEI
AFFIDAVIT OF COMPLIANCE FILED WITH
PHOTOS /AH
01-26-201004:18 PMUPDATE/NOTES01-26-10 AT 4:29 DONOVON CALLED AND
STATED HE WILL TAKE DOWN BOTH STRUCTURES
PRIOR TO THE DEADLINE /AH
01-08-201011:39 AMINITIAL INSPECTION01-08-10 WROTE NOV 441 FOR 12.16.300
UNSAFE STRUCTURE GIVEN UNTIL FEBRUARY 1,
2010 TO COMPLY OR TO APPEAR AT MARCH 11,
2010 SM HEARING /AH & GUY /60 MINS
01-08-201011:35 AMMAKE VIOLATIONMAKEVIO RECORDED AHARTSEI
09-01-200901:00 PMUPDATE/NOTESMR DALEY CALLED ADVISED HE IS HIRING
DEMO COMPANY. WISHED TO SPEAK TO YOU
FIRST. HE THOUGHT HE NEEDED YOUR OK.
PLEASE CALL 954-483-4545 CPK
08-21-200912:20 PMSTANDARD HOUSING CODE8-21-09 SY REINSPECTED THE MOBILE HOME
AND ADDITIONS THAT WERE ADDED TO THE
HOME. SINCE THE FIRST INSPECTION IN
JANUARY THE ADDITIONS HAVE CONTINUED TO
DETERIOATE. THE ROOF RAFTERS CONTINUE
TO SAG, DUE TO NOT BEING THE CORRECT
SIZE FOR THE SPAN AND THE ROOF HOLDS
WATER IN THE LOW SPOTS WHEN IT RAINS.
THIS WATER IS NOW SEEPING THROUGH THE
ROOF AND WETTING THE SHEATHING AND
RAFTERS. THESE MEMBERS WILL SOON BEGIN
TO ROT AND COLLAPSE WHEN WEAKEND. THE
MOBILE HOME HAS SEVERAL LEAKS IN IT AS
WELL. THE EAST AND WST ENDS OF THE
UNIT
HAVE BROKEN OR MISSING WINDOWS THAT ARE
ALLOWING WATER TO ENTER THE WALL AND
ROT
IT OUT. THIS IS ALSO SPREADING OUT
INTO
THE FLOOR AREA. WHERE THE ADDITION WAS
ADDED TO THE SIDE OF THE HOME AT THE
S.W. CORNER, A LARGE SECTION OF THE
MOBILE HOME WALL WAS REMOVED. THIS HAS
WEAKENED THE EXTERIOR WALL AND CAUSED A
HAZARDOUS CONDITION TO EXIST DUE TO THE
LACK OF SUPPORT FOR THE ROOF. DUE TO
THE CONTINUING DETERIOATING CONDITION
OF
THE MOBILE HOME WITH NO ATTEMPT AT
REPAIRS AND THE UNSAFE CONSTRUCTION OF
THE ROOM ADDITIONS, I AM RECOMMENDING
REMOVAL OF THE ADDITIONS AND THE MOBILE
HOME.
08-13-200903:20 PMCREATE COMPLAINTCOMPLAINT RECORDED BY DWILLIS