-     My Account  
   

Log in is not required to search. In the red banner above select: I Want To > Search > Permits

Code Enforcement Detail
Code Enforcement Detail
Case Number BD12524 complainant  
Case Date 01-26-2005 address  
Origination PHONE - TELEPHONE CALL RECEIVED Status C - CLOSED
Operator hmckinne Officer ARNOLD
Fines Balance $0.00
Lien Balance $0.00
Total Balance $0.00
Property On Case
STRAP NBR C-14-35-29-A00-0090-0000 Owner DUNCAN BRUCE K + CARMEN E
Unit   Owner Address 12524 US 98
Property Address 12524 US 98 City/State/Zip SEBRING FL 33870-3168
City/State/Zip SEBRING FL 33870 Phone 954-646-7848
Case Description
NEEDS PROPERTY INSEPCTED FOR DEMOLITION/OWNER
STATES THE TIE BEAM AND FLOOR IS GONE AND THE
INSURANCE COMPANY WANTS TO REPAIR-HE WANTS TO
DEMOLISH:(THE FRONT DOOR WILL BE UNLOCKED)STEVE
ARNOLD:THIS REPORT IS BASED UPON INFORMATION
FURNISHED BY HIGHLANDS COUNTY INSPECTOR STEVE
ARNOLD. THE STRUCTURE IS AN OLDER (PRE-CODE) HOME
OF CONCRETE BLOCK CONSTRUCTION. IT HAS A RAFTER
ROOF SYSTEM WITH 1X12 SHEATHING BOARDS. ROOF IS
COVERED WITH A BLUE TARP. THE RAFTERS ARE
ATTACHED TO 2X8 PLATE BOLTED TO TOP ROW OF BLOCK
BY TOE NAIL METHOD. IT APPEARS THIS BUILDING HAS
BEEN ADDED TO AND PART OF THE NEWEST SECTION DOES
HAVE SOME TYPE OF CONNECTOR SYSTEM. THERE ARE NO
POURED CELLS IN THE WALL. THE REPORTS STATES THAT
THE WINDOW OPENINGS HAVE BEEN ENLARGED AND THE
LINTEL DOES NOT HAVE ANY BEARING AREA SUPPORTING
IT. THE RAFTER SYSTEM WILL REQUIRE CERTIFICATION
BY AN ENGINEER WHICH WILL PROBABLY REQUIRE REMOVAL
AND REPLACEMENT WITH AN ENGINEERED TRUSS ROOF.
THE ELECTRICAL SYSTEM WILL NEED TO BE UPDATED TO
PRESENT STANDARDS. THE COST OF ALL THESE ITEMS
WILL FAR EXCEED THE 50% AMOUNT REFERENCED IN
SECTION 3401.7.2.6 REQUIRING ALL ITEMS TO BE
BROUGHT UP TO CODE OR DEMOLISH THE BUILDING. THIS
IS THE OWNERS' OPTION AS TO WHICH DIRECTION THEY
WISH TO TAKE WITH THIS BUILDING. IF REPAIRS ARE
TO BE MADE THE BUILDING DEPARTMENT WILL NEED
ENGINEERED PLANS FOR THE IMPROVEMENTS TO BE MADE.
SUBMITTED BY SOL Y. MOSELEY, BUILDING OFFICIAL
Inspections/Events Detail
DATETIMEINSPECTION / EVENT TYPEINSTRUCTIONS / COMMENTS
01-21-201110:36 AMCLOSE COMPLAINTCASE CLOSED BY HMCKINNE
02-02-200510:36 AMINITIAL INSPECTION 
Copyright © 2008 – THE PLUS SERIES ® – All Rights Reserved