-     My Account  
   

Log in is not required to search. In the red banner above select: I Want To > Search > Permits

Code Enforcement Detail
Code Enforcement Detail
Case Number BD030403 complainant  
Case Date 03-04-2003 address  
Origination FIELD - FIELD INSPECTOR Status C - CLOSED
Operator hmckinne Officer SY
Fines Balance $0.00
Lien Balance $0.00
Total Balance $0.00
Property On Case
STRAP NBR C-21-33-28-010-0030-0010 Owner ELKHILL R F + JUNE T
Unit   Owner Address 1200 WEST CIRCLE
Property Address 1200 W CIRCLE ST City/State/Zip AVON PARK FL 33825
City/State/Zip AVON PARK FL 33825 Phone  
Case Description
CODE ENFORCEMENT GAVE FOR INSPECTION
Notes
2003-04-07 09:03:27THIS IS A WOOD FRAME STRUCTURE WITH A
 RAISED WOOD FLOOR SYSTEM ON BLOCK PIERS.
 THERE IS A FRONT CANOPY WITH ONLY ONE
 SUPPORT POST UNDER THE BEAM. THE REAR
 WALL OF THE HOME HAS ROTTED, OR BEEN
 TAKEN DOWN LEAVING PART OF THE ROOF
 SYSTEM WITH NO SUPPORT UNDER IT. THE
 ROOF SHEATHING HAS SEVERAL PLACES OPEN
 TO EXTERIOR. ALL RAFTERS SHOW SIGNS OF
 DETERIORATION THROUGHOUT THE HOUSE. THE
 CEILING HAS ALL FALLED DOWN DUE TO EXPO-
 SURE TO THE WEATHER. MOST INTERIOR WALL
 COVERING HAS BEEN REMOVED ALSO. THE
 WOOD FLOOR HAS SEVERAL LARGE AREAS WHERE
 THE FLOOR JOINTS AND FLOORING HAVE
 ROTTED AWAY. THE REAR PORCH ROOF IS
 SUPPORTED BY ONLY 3 OR 4 2X4'S AS PROPS
 SINCE ALL POSTS HAVE ROTTED AWAY. THIS
 IS A VERY DANGEROUS SITUATION DUE TO THE
 2X'S SLIPPING OUT OR BREAKING UNDER THE
 ROOF LAOD. MOST ELECTRICAL WIRING HAS
 BEEN REMOVED FROM THE WALLS. THE
 KITCHEN SINK AND MOST OF THE CABINETS
 HAVE BEEN REMOVED OR ROTTED DOWN DUE TO
 EXPOSURE TO THE WEATHER. THIS STRUCTURE
 IS NOT SUITABLE FOR USE AND IS BEYOND
 THE POINT OF REPAIRING. I WOULD
 RECOMMEND REMOVING THIS STRUCTURE FROM
 THE SITE.
Inspections/Events Detail
DATETIMEINSPECTION / EVENT TYPEINSTRUCTIONS / COMMENTS
04-04-200311:39 AMINITIAL INSPECTION 
Copyright © 2008 – THE PLUS SERIES ® – All Rights Reserved